Permit: T00PL00972

Parcel: 122030060


Addresses:

2136 N MADELYN AV

Inspection Status: Correction Required

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
06/01/2000 PLUMBING - GAS PRESSURE TEST Correction Required ADDTL COMMS - 1. GAS PRESSURE TEST OK 2. WATER HTR MUST HAVE ENCLOSURE 3. WATER HTR P&T DRAIN MUST BE OF APPROVED MATERIAL CPVC, COPPER, GALVANIZED AND TERMINATE 6 A.F.F. 4. WATER DISTRIBUTION INSIDE OF DWELLING MUST BE OF APPROVED MATERIAL CPVC, COPPER OR PEX 5. CAN NOT HAVE 2 FLEX CONNECTORS CONNECTED TOGETHER AT DRYER 6. WATER HTR FLU VENT MUST BE MIN 5-0 FROM WATER HTR COLLAR TO FLU CAP TERMINATE 10 MIN. ABOVE ROOF 7. GAS CLEARANCE CARD WILL BE ISSUED AT FINAL NOTE: IF DBL WALL FLU VENT IS USED YOU MUST HAVE MIN 1 CLEARANCE AROUND VENT SINGLE WALL MIN 6 CLEARANCE