Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
7781 E 33RD ST
Apply Date:
08/23/2000
Applicant:
A & D AIR COND ''T''
Description:
INSTALL NEW COOLING/HEATING SYSTEM

Outstanding Activity Conditions

Permit Number - T00ME00903
Permit Status: Expired
Permit Description: INSTALL NEW COOLING/HEATING SYSTEM
Total Outstanding Activity Conditions - 1
Date Name
08/23/2000 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T00ME00903
Permite Description: INSTALL NEW COOLING/HEATING SYSTEM
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
08/25/2000 MECHANICAL - FINAL N/A Partial Approval IVRS - Inspection 0000*
YOU CANNOT TERMINATE CONDENSATE INTO ANY WASTE VENT SMALLER THAN 2" THE VENT YOU ARE USING IS 1 1/2". HOWEVER I WILL LET THIS GO SINCE YOU USED A SANT TEE INSTEAD OF GOING OVER THE TOP OF THE VENT BUT YOU DO NEED TO INSTALL A VENT AFTER THE TRAP WHEN TERMINATING INTO A WASTE VENT CORRECT AND RECALL FOR FINAL