Permit: T00ME00903
Permit Details
Apply Date:
08/23/2000
Applicant:
A & D AIR COND ''T''
Description:
INSTALL NEW COOLING/HEATING SYSTEM
Outstanding Activity Conditions
Permit Number - T00ME00903
Permit Status: Expired
Permit Description: INSTALL NEW COOLING/HEATING SYSTEM
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
08/23/2000 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T00ME00903
Permite Description: INSTALL NEW COOLING/HEATING SYSTEM
Total Outstanding Inspections - 1
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/25/2000 | MECHANICAL - FINAL | N/A | Partial Approval | IVRS - Inspection 0000* YOU CANNOT TERMINATE CONDENSATE INTO ANY WASTE VENT SMALLER THAN 2" THE VENT YOU ARE USING IS 1 1/2". HOWEVER I WILL LET THIS GO SINCE YOU USED A SANT TEE INSTEAD OF GOING OVER THE TOP OF THE VENT BUT YOU DO NEED TO INSTALL A VENT AFTER THE TRAP WHEN TERMINATING INTO A WASTE VENT CORRECT AND RECALL FOR FINAL |