Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
6339 S MISSIONDALE RD
Apply Date:
05/09/2000
Applicant:
KELLY AIR CONDITIONING ,
Description:
AIR COND & HEAT
Contractors:
  • KELLY AIR CONDITIONING ,

Outstanding Inspections

Permit Status: Expired
Permit Number: T00ME00484
Permite Description: AIR COND & HEAT
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
05/10/2000 MECHANICAL - FINAL N/A Correction Required ADDTL COMMS - 1. READ THE MANUFACTURES DATA PLATE. YOU MUST LABEL THE DATA PLATE WITH THE PROPER HEATER KIT INSTALLED AND FUSE UNIT ACCORDINGLY. 2. A/C UNIT MUST SIT COMPLETELY ON A CONCRET PAD. BROKEN CHUNKS OF CONCRETE WILL NOT BE ACCEPTED. 3. FLEX DUCT MUST BE STRAPPED MIN. 4 APART. 1 1/2 WIDE STRAP MIN. FLEX CANNOT LAY ON THE GROUND 4. PAINT EXPOSED PVC W/SYNTHETIC LATEX PAINT. NO SPRAY PAINT. 5. INSTALL SHIELD BETWEEN HOUSE AND A/C UNIT TO PROTECT DUCT FROM WEATHER.