Permit: T00EL02752
Permit Details
Apply Date:
11/29/2000
Applicant:
MOLINA MARIE A
Description:
UPGRADE:ELECTRIC 100 AMP TO 200 AMP/REWIRE HOUSE
Permit Reviews
Permit Number - T00EL02752
Permit Status: Expired
Permit Description: UPGRADE:ELECTRIC 100 AMP TO 200 AMP/REWIRE HOUSE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/29/2000 | ELECTRICAL | 11/29/2000 | COMPLETED |
| 12/04/2000 | ELECTRICAL | 02/14/2001 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T00EL02752
Permit Status: Expired
Permit Description: UPGRADE:ELECTRIC 100 AMP TO 200 AMP/REWIRE HOUSE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/29/2000 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T00EL02752
Permite Description: UPGRADE:ELECTRIC 100 AMP TO 200 AMP/REWIRE HOUSE
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| ELECTRIC - FINAL | N/A | Not Inspected | ||
| 01/02/2001 | ELECTRIC - SERVICE UPGRADE | N/A | Denied | IVRS - Inspection 0999* WORKING CLEARENCE VIOLATION 110-26 USE LISTED AND APPROVED PVC CONDUIT LOCK NUT ON BACKWARDS USE 2 GROUND RODS SPACED AS PER CODE NEED PERMANENT METAL ADDRESS LABEL USE CORRECT SUPPORT FOR CONDUIT USE ANTI-OXIDE COMPOUND ON ALUMINUM CONDUCTORS USE CORRECT FITTING ON RISE ABOVE SUB PANEL WILL NEED PERMIT FOR REWIRING OF HOUSE |