Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T00EL02666
Permit Details
Apply Date:
11/14/2000
Applicant:
D AND D SIGNS ,
Description:
SIGN:ELECTRIC:1592
Contractors:
- D AND D SIGNS ,
Outstanding Activity Conditions
Permit Number - T00EL02666
Permit Status: Final
Permit Description: SIGN:ELECTRIC:1592
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
11/14/2000 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T00EL02666
Permit Description: SIGN:ELECTRIC:1592
Total Completed Inspections - 4
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/24/2000 | SIGN ELECTRIC | RMAJUTA | Approved | IVRS - Inspection 0999$ SIGN DISCONNECT BOX TO BE IDENTIFIED AND SUPPORTED FLEX FROM SWITCH TO TRANSFORMER TO BE SUPPORTED NOT ON CEILING GROUND WIRE IN TRANSFORMER BOX NOT CONNECTED TO ENCLOSURE TRANSFORMER TO BE SECURED TO BOX FLEX USED TO HOUSE GTO SHALL BE GROUNDED METAL FRAMES OF LETTERS AND SYMBOL SHALL BE GROUNDED IMPROPER TRANSITION FROM END OF FLEX O NEON TUBING THUR WALL MUST USE A PROPER AND LISTED FITTING THERE IS NO SUPPORT OF FLEX HOUSING GTO AT SWITCH RUN FLEX ALL THE WAY INTO FITTING NO CITY STICKER PUT ON SIGN NO CURRENT OR AMP RATING |
02/07/2001 | SIGN SHOP | LHANLY | Approved | IVRS - Inspection 0000* |
03/07/2001 | PERMIT FINALED | JSONKIN | Approved | |
03/07/2001 | SIGN INSPECTION | JSONKIN | Approved | IVRS - Inspection 0000* |