Permit: T00EL02479
Permit Details
Apply Date:
10/20/2000
Applicant:
WEINBERG JONATHAN D
Description:
UPGRADE:ELECTRIC FROM 100AMP TO 200AMP & ADD NEW CIRCUITS
Permit Reviews
Permit Number - T00EL02479
Permit Status: Expired
Permit Description: UPGRADE:ELECTRIC FROM 100AMP TO 200AMP & ADD NEW CIRCUITS
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 10/20/2000 | ELECTRICAL | 11/03/2000 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T00EL02479
Permit Status: Expired
Permit Description: UPGRADE:ELECTRIC FROM 100AMP TO 200AMP & ADD NEW CIRCUITS
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/20/2000 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T00EL02479
Permite Description: UPGRADE:ELECTRIC FROM 100AMP TO 200AMP & ADD NEW CIRCUITS
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| ELECTRIC - FINAL | N/A | Not Inspected | ||
| 12/15/2000 | ELECTRIC - SERVICE UPGRADE | N/A | Denied | IVRS - Inspection 0245* 1-2 GROUND RODS REQUIRED AT 6' MIN SPACING USE APPROVED FITTING TO CONNECT 1 1/2" LB TO PANEL ENCLOSURE BOND WATER AND GAS PIPING SYSTEMS PERMANENT ADDRESS TAG REQUIRED ALSO NOTE THAT OWNER/OCCUPANT OF RESIDENCE IS DOING THE WORK |
Completed Inspections
Permit Status: Expired
Permit Number: T00EL02479
Permit Description: UPGRADE:ELECTRIC FROM 100AMP TO 200AMP & ADD NEW CIRCUITS
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/05/2001 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection 0000* |