Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T00EL02409
Permit Details
Apply Date:
10/12/2000
Applicant:
SIGN CITY ,
Description:
SIGN ELECTRIC:1538
Outstanding Activity Conditions
Permit Number - T00EL02409
Permit Status: Expired
Permit Description: SIGN ELECTRIC:1538
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/12/2000 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T00EL02409
Permite Description: SIGN ELECTRIC:1538
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/06/2000 | SIGN SHOP | N/A | Denied | IVRS - Inspection 0999* GTO CABLING NOT PROPERLY SEPERATED FROM EASING OR OTHER CABLING GTO TO NEON CONNECTIONS NOT DONE IN PROFESSIONAL WORK MAN LIKE MANNER |
| 11/06/2000 | SIGN ELECTRIC | N/A | Denied | IVRS - Inspection 0999* SIGN SHOULD BE ON PROPERLY IDENTIFIED 20 AMP CIRCUIT LABELING THE 100 AMP MAIN BREAKER AT SERVICE PANEL DOES NOT MEET THIS REQUIREMENT |
Completed Inspections
Permit Status: Expired
Permit Number: T00EL02409
Permit Description: SIGN ELECTRIC:1538
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/27/2000 | SIGN INSPECTION | DJOHNSTO | Approved | IVRS - Inspection 0000* |