Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T00EL02409

Parcel: 134244360


Addresses:

6301 E 22ND ST


Inspection Status: Denied

Inspection History: SIGN SHOP

Permit Number - T00EL02409

Inspection Description - SIGN SHOP

Inspection Status - Denied

Date Description Inspector Results Comments
11/06/2000 SIGN SHOP Denied IVRS - Inspection 0999*
GTO CABLING NOT PROPERLY SEPERATED FROM EASING OR OTHER CABLING
GTO TO NEON CONNECTIONS NOT DONE IN PROFESSIONAL WORK MAN LIKE MANNER
10/27/2000 SIGN SHOP Denied IVRS - Inspection 0999*
GTO CABLING NOT PROPERLY SPACED, OR SUPPORTED OFF METAL
NEON TUBE IN LETTER A NOT PROPERLY TIED TO SUPPORTS CHECK OTHER LETTERS ALSO
JUNCTION BOX FROM PRIMARY CIRCUIT NOT WATER PROOF
GFI OUTLET ATTACHED TO SIGN NOT PROPERLY SUPPORTED
OPENING CUT OUT FOR SWITCH AT EAST END NOT LARGE ENOUGH TO PROVIDE PROPER ACCESS FOR FUTURE REPAIR (EDGES COULD CUT WIRING)
LID ON RACEWAY NOT SUFFCIENTLY WATER TIGHT
PLEASE IDENTIFY SIGN CIRCUIT IN SERVICE PANEL NOTE PLEASE CALL SIGN INSTALLER