Apply Date:
06/13/2000
Applicant:
ARC ELECTRIC CO INC
Description:
SERVICE UPGRADE
Contractors:
- ARC ELECTRIC CO INC
Outstanding Inspections
Permit Status: Expired
Permit Number: T00EL01477
Permite Description: SERVICE UPGRADE
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/15/2000 | ELECTRIC - FINAL | N/A | Correction Required | ADDTL COMMS - 1. WINDOW A/C CIRCUIT APPEARS 220W. INSTALL PROPER 2 POLE BREAKER, CAUTION CARD ON A/C FRAYED. 2. LOOSE CONNECTORS AND COUPLINGS THROUGHOUT CONDUIT CROOKED 3. ROMEX IS NOT THE PROPER WIRING METHOD TO BE INSTALLED E.M.T. CONDUIT 4. WILL NEED TO VERIFY IF INFACT ALL HOUSE CIRCUITS ARE RATED FOR 20 AMPS ( THE CIRCUITS FROM EXTERIOR PANEL BOARD) 5. EXPOSE GROUND RODS 6. INSTALL A GAS BOND 7. NEED A K.O. SEAL AT BOTTOM OF PANEL 8. NEED PERMANENT ADDRESS TAG ENGRAVED OR RAISED |