Permit: T00EL01477

Parcel: 116211400


Addresses:

60 S CUESTA AV

Inspection Status: Correction Required

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
06/15/2000 ELECTRIC - FINAL Correction Required ADDTL COMMS - 1. WINDOW A/C CIRCUIT APPEARS 220W. INSTALL PROPER 2 POLE BREAKER, CAUTION CARD ON A/C FRAYED. 2. LOOSE CONNECTORS AND COUPLINGS THROUGHOUT CONDUIT CROOKED 3. ROMEX IS NOT THE PROPER WIRING METHOD TO BE INSTALLED E.M.T. CONDUIT 4. WILL NEED TO VERIFY IF INFACT ALL HOUSE CIRCUITS ARE RATED FOR 20 AMPS ( THE CIRCUITS FROM EXTERIOR PANEL BOARD) 5. EXPOSE GROUND RODS 6. INSTALL A GAS BOND 7. NEED A K.O. SEAL AT BOTTOM OF PANEL 8. NEED PERMANENT ADDRESS TAG ENGRAVED OR RAISED
06/15/2000 ELECTRIC - FINAL Denied IVRS - Inspection 0999*