Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
COMMERCIAL ALTERATION
Address:
801 E 46TH ST
Address NEW:
801 E 46TH ST
Apply Date:
11/20/2000
Applicant:
HOUSTON CONSTRUCTION INC , ED /METRO
Description:
TI:OFFICE/MANUFACTURING
Contractors:
  • HOUSTON CONSTRUCTION INC , ED

Permit Reviews

Permit Number - T00CM05608
Permit Status: Expired
Permit Description: TI:OFFICE/MANUFACTURING
Start Date Submittal Complete Date Status  
01/17/2001 REVISION 01/17/2001 COMPLETED Review Details
11/20/2000 COMMERCIAL TI 12/07/2000 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T00CM05608
Permit Status: Expired
Permit Description: TI:OFFICE/MANUFACTURING
Total Outstanding Activity Conditions - 1
Date Name
11/20/2000 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T00CM05608
Permite Description: TI:OFFICE/MANUFACTURING
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
SIGN - FINAL N/A Not Inspected

Completed Inspections

Permit Status: Expired
Permit Number: T00CM05608
Permit Description: TI:OFFICE/MANUFACTURING
Total Completed Inspections - 15
Date Description Inspector Results Comments
12/07/2000 PLUMBING - ROUGH, SOIL RMYERS Approved IVRS - Inspection 0000*
ABS UNDERGROUND OK WATER TEST OK TO 42"
CLOSET RINGS OK
OK TO COVER
12/19/2000 FRAMING DWITT Approved IVRS - Inspection 0000*
12/20/2000 MECHANICAL - ABOVE CEILING CWILLIAM Approved IVRS - Inspection 0000*
12/20/2000 MECHANICAL - INTERMEDIATE CWILLIAM Approved IVRS - Inspection 0000*
12/21/2000 SHEET ROCK NAILING DWITT Approved IVRS - Inspection 0000*
12/28/2000 PLUMBING - SEWER HCS CONNECT RMYERS Approved IVRS - Inspection 0000*
ABS SEWER OK
WATER TEST OK
SEWER TAP OK
OK TO COVER
12/29/2000 PLUMBING - PROGRESS RMYERS Approved IVRS - Inspection 0000*
OK FOR TEMP C OF O PENDING APPROVAL OF THE OTHER INSPECTORS
12/29/2000 ELECTRIC - INTERMEDIATE MCAPISTR Approved IVRS - Inspection 0000*
INSTALLATION OF SERVICE EQUIPMENT AND FEEDERS APPROVED. OVERHEAD WIRING
12/31/2000 BUILDING - FINAL DWITT Approved IVRS - Inspection 0000*
OKAY TO MOVE MACHINERY IN
01/11/2001 FIRE SPKLR - FINAL FIRE Approved
01/11/2001 PLUMBING - FINAL RMYERS Approved IVRS - Inspection 0000*
01/11/2001 PLUMBING - ABOVE CEILING RMYERS Approved IVRS - Inspection 0000*
PLUMBING FINAL OK
OK FOR C OF P PENDING ANY OTHER INSPECTION
NO GAS ON THIS PERMIT
01/12/2001 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection 0000*
01/19/2001 ELECTRIC - FINAL RMAJUTA Approved IVRS - Inspection 0000*
01/19/2001 ELECTRIC - FINAL RMAJUTA Approved IVRS - Inspection 0000*
ELECT FINAL OK TO OPERATE EQUIPMENT
INSTALL CIRCUIT BREAKERS COMPLING WITH PANEL LISTING ALL GE REQUIRED
INSTALL PROTECTION WHERE CORD PENETRATE MACHINERY ENCLOSURE
CORRECT ALL PANEL SCHEDULES AND APPROVED PLANS LEFT FOR OWNER
HARD WIRE KIRSH DRILLING MACHINE COMING OFF POLE (HARDISON)

Documents

File Name Document Type  
None DOCUMENTS VIEW