Permit Details

Status:
Expired
Type:
MULTI FAMILY NEW
Address:
224 W ROGER RD
Apply Date:
11/06/2000
Applicant:
N/A
Description:
FOURPLEX:TD#14-93-08
Contractors:
  • COLAR GROUP INC ,

Permit Reviews

Permit Number - T00CM05436
Permit Status: Expired
Permit Description: FOURPLEX:TD#14-93-08
Start Date Submittal Complete Date Status  
11/06/2000 RESIDENTIAL BLDG/ZONING/FLOOD 02/20/2001 COMPLETED Review Details

Outstanding Inspections

Permit Status: Expired
Permit Number: T00CM05436
Permite Description: FOURPLEX:TD#14-93-08
Total Outstanding Inspections - 5
Last Inspection Date Description Inspector Results Comments
U VALUE FOR WINDOW N/A Not Inspected
ELECTRIC - UFER N/A Not Inspected
ELECTRIC - TEMPORARY SERVICE N/A Not Inspected
05/02/2001 ELECTRIC - FINAL N/A Partial Approval 1) BATH AND WASHER RECEPTICLES ON SAME CIRCUIT-SEPERATE WASHER NEEDS OWN CIRCUIT IN PANEL 2) BATHROOM GFI NOT IN-WIRES ENERGIZED-SHUT CIRCUIT AS BATH GFI SHOULD BE SEPERATE-PANEL SHOULD HAVE A SEPERATE WASHER AND BATH BREAKER 3) WHAT CAME ABOUT WITH THE JUMPER FROM THE GROUND BAR TO THE NEUTRAL BAR AT THE SERVICE AS WE HAD DISCUSSED? DID YOU FIND THE ORIGINAL JUMPER IN THE SERVICE?
05/03/2001 BUILDING - FINAL N/A Partial Approval IVRS - Inspection 0000* STRIPE PARKING LOT
OK FOR OCCUPANCY APPROVAL IS BEING HELD FOR EMONAHAN'S APPROVAL OF PARKING LOT

Completed Inspections

Permit Status: Expired
Permit Number: T00CM05436
Permit Description: FOURPLEX:TD#14-93-08
Total Completed Inspections - 11
Date Description Inspector Results Comments
12/05/2000 PLUMBING - ROUGH, SOIL JSTANLEY Approved IVRS - Inspection 0000*
TEST OK ON UNDERGROUND SOIL DON'T FORGET TO INSTALL C.O.'s END OF RUN
PLEASE WRAP ALL ABS IN CONCRET
NOTE NO WATER UNDER SLAB
12/20/2000 ROOF NAILING EMONAHAN Approved IVRS - Inspection 0000*
12/20/2000 EXT METAL CLIPS/EXT SHEATHING EMONAHAN Approved IVRS - Inspection 0000*
02/02/2001 MECHANICAL - INTERMEDIATE CWILLIAM Approved IVRS - Inspection 0000*
02/06/2001 PLUMBING - INTERMEDIATE JSTANLEY Approved IVRS - Inspection 0000*
02/22/2001 FRAMING EMONAHAN Approved IVRS - Inspection 0000*
02/23/2001 ELECTRIC - INTERMEDIATE RMAJUTA Approved IVRS - Inspection 0000*
03/01/2001 STUCCO MESH EMONAHAN Approved IVRS - Inspection 0000*
03/13/2001 SHEET ROCK NAILING EMONAHAN Approved IVRS - Inspection 0000$ INSTALLSCREWS WHERE INDICATED THEN OK
04/23/2001 ELECTRIC - CABLE DROP RMAJUTA Approved IVRS - Inspection 0000* FOR FINAL VERIFY NEUTRAL IS TIED TO CAN-COULD NOT FIND CONNECTION, AND WATER BOND
04/30/2001 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection 0000*

Documents

File Name Document Type  
001_SITE PLAN.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW