Permit: T00CM04757
Permit Details
Status:
Final
Type:
SINGLE FAMILY ALTERATION
Address:
626 W THURBER RD
Address NEW:
626 W THURBER RD
Apply Date:
09/25/2000
Applicant:
MILLIGAN MICHAEL J & JOAN M JT/R
Description:
ENCLOSE :PORCH TO ROOM
Permit Reviews
Permit Number - T00CM04757
Permit Status: Final
Permit Description: ENCLOSE :PORCH TO ROOM
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/07/2001 | REVISION | 03/09/2001 | COMPLETED |
| 09/25/2000 | RESIDENTIAL BLDG/ZONING | 10/04/2000 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T00CM04757
Permit Status: Final
Permit Description: ENCLOSE :PORCH TO ROOM
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/25/2000 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T00CM04757
Permit Description: ENCLOSE :PORCH TO ROOM
Total Completed Inspections - 6
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/12/2001 | FRAMING | JRIVA | Approved | IVRS - Inspection 0000* |
| 12/19/2001 | ELECTRIC - INTERMEDIATE | JRIVA | Approved | IVRS - Inspection 0000*/ 1) ELECTRIC SPLICES NOT ALLOWED IN WALL CAVITY. MUST TERMINATE ALL WIRES IN AN ACCESSIBLE BOX, 2 LOCATIONS ON EAST WALL 2) GROUND ALL METAL ELECTRIC BOXES 3) ELECTRIC SUB PANEL MUST HAVE AN ISOLATED NEUTRAL BAR MINIMUM #10 4) ELECTRIC SUB PANEL REQUIRES A GROUND WIRE 5) COLOR CODE NEUTRAL WIRE WHITE ON EACH END. OK TO INSULATE AND DRYWALL CEILING AND NORTH, SOUTH AND WEST WALLS. DO NOT COVER SPLICES IN EAST WALL |
| 09/05/2002 | PERMIT FINALED | DBRITO | Approved | |
| 09/06/2002 | ELECTRIC - FINAL | DBRITO | Approved | IVRS - Inspection 0000* |
| 09/06/2002 | BUILDING - FINAL | DBRITO | Approved | IVRS - Inspection 0000* |
| 09/06/2002 | SHEET ROCK NAILING | DBRITO | Approved | IVRS - Inspection 0000* |