Permit Details

Status:
Final
Type:
SINGLE FAMILY NEW
Address:
3085 S BECK DR
Apply Date:
08/18/2000
Applicant:
NEW WORLD HOMES
Description:
SFR:TD#14-77-21
Contractors:
  • NEW WORLD HOMES

Permit Reviews

Permit Number - T00CM04112
Permit Status: Final
Permit Description: SFR:TD#14-77-21
Start Date Submittal Complete Date Status  
08/18/2000 RESIDENTIAL BLDG/ZONING/FLOOD 02/13/2001 COMPLETED Review Details

Completed Inspections

Permit Status: Final
Permit Number: T00CM04112
Permit Description: SFR:TD#14-77-21
Total Completed Inspections - 23
Date Description Inspector Results Comments
10/06/2000 PLUMBING - SEWER HCS CONNECT RFREIDIN Approved IVRS - Inspection 0000*
10/06/2000 PLUMBING - YARD WTR LINE/TEST RFREIDIN Approved IVRS - Inspection 0000*
10/06/2000 PLUMBING - ROUGH, SOIL RFREIDIN Approved IVRS - Inspection 0000*
10/24/2000 ELECTRIC - UFER JRIVA Approved IVRS - Inspection 0000*
10/24/2000 BUILDING PRE-SLAB JRIVA Approved IVRS - Inspection 0000*
10/24/2000 STEM WALL/RETAINING WALL JRIVA Approved IVRS - Inspection 0000*
10/24/2000 EXCAVATION/LAYOUT REBAR & ZON JRIVA Approved IVRS - Inspection 0000*
12/01/2000 ELECTRIC - TEMPORARY SERVICE BSTEVENS Approved IVRS - Inspection 0000*
12/01/2000 ELECTRIC - CABLE DROP BSTEVENS Approved IVRS - Inspection 0000*
12/01/2000 ROOF NAILING BSTEVENS Approved IVRS - Inspection 0000*
12/01/2000 EXT METAL CLIPS/EXT SHEATHING BSTEVENS Approved IVRS - Inspection 0000*
12/29/2000 MECHANICAL - INTERMEDIATE RFREIDIN Approved IVRS - Inspection 0000*
12/29/2000 PLUMBING - GAS PRESSURE TEST RFREIDIN Approved IVRS - Inspection 0000*
12/29/2000 PLUMBING - INTERMEDIATE RFREIDIN Approved IVRS - Inspection 0000*
12/29/2000 ELECTRIC - INTERMEDIATE RFREIDIN Approved IVRS - Inspection 0000*
12/29/2000 STUCCO MESH RFREIDIN Approved IVRS - Inspection 0000*/RETURN LATH TO STEM AT POP OUTS.
12/29/2000 FRAMING RFREIDIN Approved IVRS - Inspection 0000*/1. MISSING A.B. AT INTERIOR SHEAR. 2. ALL DROP CIELINGS NEED RAT RUNS AT STURCTUAL B/CHORD 10' O.C. 3. GABLE END HINGE BRACES X DOWN/TO TOP PLATE 4. H.D. NOT TYPE SPEC'D ON PLAN 5. CAN'T READ SHEAR SCHEDULE, INK IS SMEARED. 6. NEED COMB/RELIEF DUCTS GARAGE. 7. MISSING GAS FLUES. 8. FILL ALL NAIL HOLES TRUSS CLIPS. 9. SECURE ALL H20 STUBS AT LAVS, TOLIETS ECT. 10. H20 LINE REFRIGERATOR OUT OF WALL (CHIP CONC.) MOVE BACK 11. INT. WALL STUD O.C. OVER SPAN CENTER ROOM N/SIDE AT HALL.
02/13/2001 SHEET ROCK NAILING RFREIDIN Approved IVRS - Inspection 0000*
04/20/2001 PERMIT FINALED BSTEVENS Approved
04/20/2001 MECHANICAL - FINAL BSTEVENS Approved IVRS - Inspection 0000*
04/20/2001 PLUMBING - FINAL BSTEVENS Approved IVRS - Inspection 0000*
04/20/2001 ELECTRIC - FINAL BSTEVENS Approved IVRS - Inspection 0000*
04/20/2001 BUILDING - FINAL BSTEVENS Approved IVRS - Inspection 0000*