Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY NEW
Address NEW:
3944 N PLACITA LA VINA
Apply Date:
08/11/2000
Applicant:
STARSYS DEVELOPMENT COMPANY ,
Description:
SFR:TD#14-83-83
Contractors:
  • STARSYS DEVELOPMENT COMPANY ,

Completed Inspections

Permit Status: Final
Permit Number: T00CM03985
Permit Description: SFR:TD#14-83-83
Total Completed Inspections - 21
Date Description Inspector Results Comments
09/15/2000 ELECTRIC - UFER MCAPISTR Approved IVRS - Inspection 0000*
09/15/2000 BUILDING PRE-SLAB MCAPISTR Approved IVRS - Inspection 0000*
09/15/2000 STEM WALL/RETAINING WALL MCAPISTR Approved IVRS - Inspection 0000*
09/15/2000 EXCAVATION/LAYOUT REBAR & ZON MCAPISTR Approved IVRS - Inspection 0000*
12/04/2000 PLUMBING - YARD WTR LINE/TEST JRIVA Approved IVRS - Inspection 0000*
12/04/2000 ROOF NAILING JRIVA Approved IVRS - Inspection 0999*
12/04/2000 EXT METAL CLIPS/EXT SHEATHING JRIVA Approved IVRS - Inspection 0999*/1. NORTH AND SOUTH WALLS HAVE 2 LAYERS OF O.S.B. SHIMMING UP AND BEARING THE WEIGHT OF THE TRUSSES AND THE TRUSS CLIPS DO NOT ATTACH TO THE DOUBLE TOP PLATE. PROVIDE CITY OF TUCSON, ENGINEERS, AND YOUR ARCHITECT PROVIDE AN APPROVED DETAIL OF THIS CONSTRUCTION. 2. POST TENSION PLANS MUST BE APPROVED BY CITY OF TUCSON. 3. CITY APPROVED TRUSS DRAWINGS MUST BE ON SITE. 4. MANY ROOF PANELS LOOSE REMOVE SHINERS AND RENAIL. 5. 1/8" END AND EDGE CLEARANCE REQUIRED ON O.S.B. ROOF PANELS.
01/16/2001 MECHANICAL - INTERMEDIATE JRIVA Approved IVRS - Inspection 0000*
01/16/2001 PLUMBING - GAS PRESSURE TEST JRIVA Approved IVRS - Inspection 0000*
01/16/2001 ELECTRIC - TEMPORARY SERVICE JRIVA Approved IVRS - Inspection 0000*
01/16/2001 ELECTRIC - CABLE DROP JRIVA Approved IVRS - Inspection 0000*
01/16/2001 FRAMING JRIVA Approved IVRS - Inspection 0000*
01/18/2001 PLUMBING - INTERMEDIATE JRIVA Approved IVRS - Inspection 0000*
01/18/2001 ELECTRIC - INTERMEDIATE JRIVA Approved IVRS - Inspection 0000*
02/23/2001 STUCCO MESH JRIVA Approved IVRS - Inspection 0000*
02/27/2001 SHEET ROCK NAILING JRIVA Approved IVRS - Inspection 0000*
05/03/2001 PERMIT FINALED JRIVA Approved
05/03/2001 MECHANICAL - FINAL JRIVA Approved IVRS - Inspection 0000*
05/03/2001 PLUMBING - FINAL JRIVA Approved IVRS - Inspection 0000*
05/03/2001 ELECTRIC - FINAL JRIVA Approved IVRS - Inspection 0000*
05/03/2001 BUILDING - FINAL JRIVA Approved IVRS - Inspection 0000*

Documents

File Name Document Type  
MODEL PLAN INFO T00CM03985 DOCUMENTS VIEW
None DOCUMENTS VIEW
001_A-0.TIF CONSTRPLANS VIEW
None CONSTRPLANS VIEW