Permit: T00CM03702
Permit Details
Apply Date:
07/26/2000
Applicant:
EDGE KELLY
Description:
ENCLOSURE:GARAGE TO BEDROOM/BATHROOM
Permit Reviews
Permit Number - T00CM03702
Permit Status: Expired
Permit Description: ENCLOSURE:GARAGE TO BEDROOM/BATHROOM
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/26/2000 | RESIDENTIAL BLDG/ZONING/FLOOD | 02/07/2001 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T00CM03702
Permit Status: Expired
Permit Description: ENCLOSURE:GARAGE TO BEDROOM/BATHROOM
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 07/26/2000 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T00CM03702
Permite Description: ENCLOSURE:GARAGE TO BEDROOM/BATHROOM
Total Outstanding Inspections - 10
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| REINFORCED MASONRY PRE-GROUT | N/A | Not Inspected | ||
| SHEET ROCK NAILING | N/A | Not Inspected | ||
| BUILDING - FINAL | N/A | Not Inspected | ||
| ELECTRIC - FINAL | N/A | Not Inspected | ||
| PLUMBING - FINAL | N/A | Not Inspected | ||
| 08/18/2000 | PLUMBING - ROUGH, SOIL | N/A | Denied | 1. SANITARY TEES USED FOR VENTING NOT ALLOWED LYING IN FLAT POSITION. 2. TUB IS NOT VENTED. 3. SHOWER IS NOT VENTED 4. SHOWER TRAP AND DRAIN TOO BE 2" MINIMUM. 5. I SUGGEST YOU HIRE A LICENSED PLUMBER. |
| 09/19/2000 | FRAMING | N/A | Not ready for Inspection | IVRS - Inspection 0000*/1. COMPLETE ALL INTERMEDIATES. 2. CHANGE PLANS TO REFLECT PLUMB. 3. COMPLETE PLUMB. |
| 09/19/2000 | ELECTRIC - INTERMEDIATE | N/A | Not ready for Inspection | IVRS - Inspection 0000* |
| 09/19/2000 | PLUMBING - INTERMEDIATE | N/A | Not ready for Inspection | IVRS - Inspection 0000* |
| 09/19/2000 | PLUMBING - GAS PRESSURE TEST | N/A | Not ready for Inspection | IVRS - Inspection 0000* |