Permit: T00CM03702

Parcel: 136176050


Addresses:

8340 E RUBY DR


Inspection Status: Denied

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T00CM03702

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Denied

Date Description Inspector Results Comments
08/18/2000 PLUMBING - ROUGH, SOIL Denied 1. SANITARY TEES USED FOR VENTING NOT ALLOWED LYING IN FLAT POSITION. 2. TUB IS NOT VENTED. 3. SHOWER IS NOT VENTED 4. SHOWER TRAP AND DRAIN TOO BE 2" MINIMUM. 5. I SUGGEST YOU HIRE A LICENSED PLUMBER.
08/10/2000 PLUMBING - ROUGH, SOIL Denied
08/08/2000 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0269*1. UNCOVER CONNECTION TO EXISTING SEWER FROM NEW CONNECTION 2. NEED 42" OF WATER INLINES. NO ANSWER AT DOOR
08/04/2000 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*1. UNCOVER PLUMB. 2. NEED WATER TEST 42" FROM F.F. 3. NO PLANS. 4. NO ANSWER AT DOOR.