Permit Details

Status:
C of o
Type:
COMMERCIAL ADDITION
Address:
810 W WETMORE RD
Address NEW:
810 W WETMORE RD
Apply Date:
07/25/2000
Applicant:
JASON G MILLER/METRO
Description:
ADDITION:OFFICE & CANOPY/REMODEL INTERIOR 1ST FL
Architects:
  • SHELLER, GEORGE FREDRICK
Contractors:
  • RELIANCE COMMERCIAL CONSTRUCTION

Permit Reviews

Permit Number - T00CM03689
Permit Status: C of o
Permit Description: ADDITION:OFFICE & CANOPY/REMODEL INTERIOR 1ST FL
Start Date Submittal Complete Date Status  
05/30/2001 REVISION 06/15/2001 COMPLETED Review Details
08/31/2000 3RD PARTY REVIEW-COMMERCIAL 11/06/2000 COMPLETED Review Details
08/31/2000 SITE 10/18/2000 COMPLETED Review Details
10/23/2000 RESUBMITTAL 11/21/2000 COMPLETED Review Details
11/06/2000 RESUBMITTAL 11/21/2000 COMPLETED Review Details

Completed Inspections

Permit Status: C of o
Permit Number: T00CM03689
Permit Description: ADDITION:OFFICE & CANOPY/REMODEL INTERIOR 1ST FL
Total Completed Inspections - 28
Date Description Inspector Results Comments
12/01/2000 STEM WALL/RETAINING WALL EMONAHAN Approved
12/05/2000 EXCAVATION/LAYOUT REBAR & ZON AMATHIES Approved ADJACENT TO SOUTH BAY WALL AND EAST SHOWROOM
12/17/2000 ELECTRIC - UNDERGROUND RHOLLAND Approved IVRS - Inspection 0000*
OK 1" CONDUIT TO FLOOR BOXES RECEPTION AREA
AUTO SHOP COVERED WITHOUT INSPECTION
12/26/2000 PLUMBING - ROUGH, SOIL JSTANLEY Approved IVRS - Inspection 0000*
WASH BAY
12/26/2000 REINFORCED MASONRY PRE-GROUT AMATHIES Approved IVRS - Inspection 0000*
01/30/2001 ELECTRIC - CABLE DROP RHOLLAND Approved IVRS - Inspection 0000*
OK CABLE DROP ONLY
NOTE IF SATURDAY AFTER HOURS INSPECTION IS NOT PAID BY 3:00 PM 01/30/01 A STOP WORK ORDER WILL BE ISSUED
03/09/2001 ROOF NAILING AMATHIES Approved IVRS - Inspection 0000*
03/29/2001 BUILDING ABOVE CEILING EMONAHAN Approved IVRS - Inspection 0000*
03/29/2001 BUILDING ABOVE CEILING EMONAHAN Approved IVRS - Inspection 0000*
04/17/2001 FRAMING EMONAHAN Approved IVRS - Inspection 0000$
04/26/2001 SHEET ROCK NAILING EMONAHAN Approved IVRS - Inspection 0000*
06/07/2001 SIGN - FINAL JSONKIN Approved IVRS - Inspection 0000*
06/07/2001 MECHANICAL - ABOVE CEILING CWILLIAM Approved IVRS - Inspection 0000*1)A/C-A-NO GAS CONN.?
2)CARRIER UNIT <CONDENSER>SECURE TO PAD.IT RM.3)A/C COMBO #4 IMPROPER FLEX CONNECTOR SIZE.
06/07/2001 PLUMBING - FINAL JSTANLEY Approved IVRS - Inspection 0000*SEE INFO ON NEW PERMIT SAME ADDRESS.
06/07/2001 PLUMBING - ABOVE CEILING JSTANLEY Approved IVRS - Inspection 0000*
06/07/2001 PLUMBING - INTERMEDIATE JSTANLEY Approved IVRS - Inspection 0000*
06/07/2001 STUCCO MESH EMONAHAN Approved IVRS - Inspection 0000*
06/07/2001 BUILDING PRE-SLAB EMONAHAN Approved IVRS - Inspection 0000*
06/09/2001 ELECTRIC - INTERMEDIATE RHOLLAND Approved IVRS - Inspection 0000*1)LIGHT FIXTURES TO BE FULLY SHEIDED-4 AT SOUTHSIDE.DO PREVIOUS INSPECTION THAT ARE NOTED AS NOT DONE OK ROOM #120,121.CHECK SERVICE NEXT INSPECTION.
06/12/2001 ELECTRIC - FINAL RHOLLAND Approved IVRS - Inspection 0000*OK FINAL SUBJECT TO NOTE ON PRMIT # T00CM03690.
06/15/2001 FIRE SPKLR - FINAL LTHOMAS Approved
06/15/2001 FIRE SPKLR - OH PIPING & HYDRO LTHOMAS Approved
06/15/2001 FIRE SPKLR - UG PIPING FLUSH LTHOMAS Approved
06/15/2001 FIRE SPKLR - UG, PIPING, HYDRO LTHOMAS Approved
06/15/2001 BUILDING - FINAL EMONAHAN Approved
06/15/2001 EXT METAL CLIPS/EXT SHEATHING EMONAHAN Approved
06/26/2001 OUTDOOR LIGHTING FINAL RHOLLAND Approved IVRS - Inspection 0000*OK FINAL
07/03/2001 PERMIT FINALED RHOLLAND Approved