Permit: T00CM03674
Permit Details
Apply Date:
07/24/2000
Applicant:
STICKLEY PANNO GROUP
Description:
ADDITION:OFFICE
Architects:
- STICKLEY PANNO GROUP
Contractors:
- WARREN DEVELOPMENT INC , A B
Permit Reviews
Permit Number - T00CM03674
Permit Status: Final
Permit Description: ADDITION:OFFICE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/09/2001 | REVISION | 03/09/2001 | COMPLETED |
| 03/22/2001 | REVISION | 03/22/2001 | COMPLETED |
| 07/24/2000 | COMMERCIAL NEW | 10/16/2000 | COMPLETED |
| 10/16/2000 | RESUBMITTAL | 11/20/2000 | COMPLETED |
| 10/16/2000 | SITE | 12/08/2000 | COMPLETED |
| 12/08/2000 | RESUBMITTAL | 12/11/2000 | COMPLETED |
| 12/11/2000 | RESUBMITTAL | 12/12/2000 | COMPLETED |
| 12/12/2000 | RESUBMITTAL | 12/12/2000 | COMPLETED |
| 12/12/2000 | RESUBMITTAL | 02/06/2001 | COMPLETED |
Completed Inspections
Permit Status: Final
Permit Number: T00CM03674
Permit Description: ADDITION:OFFICE
Total Completed Inspections - 21
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/27/2000 | PLUMBING - ROUGH, SOIL | JSTANLEY | Approved | IVRS - Inspection 0000* PROVIDE FULL SIZE CO ON BRANCH OVER FIVE FOOT AND AS PER APPROVED PLAN UNCOVER TO POINT OF CONNECTION OF EXISTING SEWER NEED TO SEE NEW LOCATION OF TWO WAY C.O. PLEASE PROVIDE APPROVED REVISED PLANS IF NOT INSTALLED AS PER APPROVED PLANS |
| 01/09/2001 | ELECTRIC - UFER | RHOLLAND | Approved | IVRS - Inspection 0000* USE LISTED AND APPROVED PVC CONDUIT |
| 01/09/2001 | BUILDING PRE-SLAB | EMONAHAN | Approved | IVRS - Inspection 0000* |
| 01/09/2001 | STEM WALL/RETAINING WALL | EMONAHAN | Approved | IVRS - Inspection 0000* |
| 01/09/2001 | EXCAVATION/LAYOUT REBAR & ZON | EMONAHAN | Approved | IVRS - Inspection 0000* |
| 02/13/2001 | ROOF NAILING | EMONAHAN | Approved | IVRS - Inspection 0000* |
| 02/21/2001 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 02/21/2001 | EXT METAL CLIPS/EXT SHEATHING | EMONAHAN | Approved | IVRS - Inspection 0000$ WHEN SCREWED PER CODE |
| 02/26/2001 | ELECTRIC - TEMPORARY SERVICE | RMAJUTA | Approved | IVRS - Inspection 0000* VERIFY REJECT PINS ON FINAL |
| 02/27/2001 | FRAMING | EMONAHAN | Approved | IVRS - Inspection 0000* |
| 03/07/2001 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection 0000* OK WALLS |
| 03/08/2001 | SHEET ROCK NAILING | EMONAHAN | Approved | IVRS - Inspection 0000* |
| 03/25/2001 | PLUMBING - PROGRESS | RMYERS | Approved | IVRS - Inspection 0000* 1) OK TO SHEET ROCK ELECTRIC DRINKING FOUNTAIN AND UTILITY SINK 2) OK TO BACKFILL 2" WASTE FROM SAME CLEAN OUT COVER TO BE INSTALLED IN ASPHALT AND PATCHED 3) WATER HEATER MAY NEED CORRECTIONS: A) SUPPORT EXPANSION TANK-DO YOU NEED A DIELECTRIC UNION? B) FULL SIZE T AND P DRAIN TO APPROVED LOCATION C) FULL SIZE PAN DRAIN TO APPROVED LOCATION |
| 03/25/2001 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection 0000* |
| 03/25/2001 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection 0000* |
| 03/26/2001 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 03/26/2001 | BUILDING ABOVE CEILING | EMONAHAN | Approved | IVRS - Inspection 0000* |
| 03/28/2001 | MECHANICAL - FINAL | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 03/29/2001 | OUTDOOR LIGHTING FINAL | RHOLLAND | Approved | IVRS - Inspection 0000* |
| 03/29/2001 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection 0000* NOTE: PANEL SHOULD BE LABELED ON OUTSIDE OF COVER FOR EASY RECOGNITION |
| 04/03/2001 | SIGN - FINAL | JSONKIN | Approved | IVRS - Inspection 0000* |