Permit: T00CM03580
Permit Details
Status:
Final
Type:
SINGLE FAMILY NEW
Address:
2785 W PLACITA SOMBRA CHULA
Address NEW:
2785 W PLACITA SOMBRA CHULA
Apply Date:
07/18/2000
Applicant:
BRAXTON GROUP
Description:
SFR
Contractors:
- BRAXTON GROUP
Permit Reviews
Permit Number - T00CM03580
Permit Status: Final
Permit Description: SFR
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 07/18/2000 | RESIDENTIAL BLDG/ZONING/FLOOD/WWM | 08/15/2000 | COMPLETED |
| 12/14/2000 | REVISION | 12/14/2000 | COMPLETED |
Completed Inspections
Permit Status: Final
Permit Number: T00CM03580
Permit Description: SFR
Total Completed Inspections - 22
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/26/2000 | PLUMBING - YARD WTR LINE/TEST | RAIELLO | Approved | IVRS - Inspection 0000* |
| 09/26/2000 | PLUMBING - ROUGH, SOIL | RAIELLO | Approved | IVRS - Inspection 0000* |
| 10/06/2000 | ELECTRIC - UFER | DQUINN | Approved | IVRS - Inspection 0000* |
| 10/06/2000 | BUILDING PRE-SLAB | DQUINN | Approved | IVRS - Inspection 0000* |
| 10/06/2000 | STEM WALL/RETAINING WALL | DQUINN | Approved | IVRS - Inspection 0000* |
| 10/06/2000 | EXCAVATION/LAYOUT REBAR & ZON | DQUINN | Approved | IVRS - Inspection 0000* |
| 11/14/2000 | ROOF NAILING | RAIELLO | Approved | IVRS - Inspection 0000* |
| 11/14/2000 | EXT METAL CLIPS/EXT SHEATHING | RAIELLO | Approved | IVRS - Inspection 0000*/1. BACK PORCH NOT INSTALLED AT THIS TIME. 2. WILL NEED REVISION FOR MODIFICATION TO FAMILY ROOM DOOR. 3. CHECK SHEAR WALL PARIMETER OF HOUSE. OK TO DRY IN ROOF OVER MAIN RESIDENCE. |
| 12/15/2000 | MECHANICAL - INTERMEDIATE | DBRITO | Approved | IVRS - Inspection 0000* |
| 12/15/2000 | PLUMBING - INTERMEDIATE | DBRITO | Approved | IVRS - Inspection 0000* |
| 12/15/2000 | ELECTRIC - INTERMEDIATE | DBRITO | Approved | IVRS - Inspection 0000* |
| 12/20/2000 | PLUMBING - GAS PRESSURE TEST | RCHAVEZ | Approved | IVRS - Inspection 0999* |
| 12/26/2000 | FRAMING | DBRITO | Approved | IVRS - Inspection 0999*/1. DBL TJI NEED TO BE SOLIA MEMBER PROVIDE WEB STIFFERNERS. 2. CHECK RED HEADS THRU OUT. 3. PROVIDE HANGERS AT PORCH RAFTER TO LEDGER CONNECTION. 4. WATER CLOSET SHOULD BE 15" AWAY FROM ANY WALL. |
| 01/17/2001 | SEPTIC - SYSTEM | DBRITO | Approved | IVRS - Inspection 0000* |
| 01/29/2001 | SHEET ROCK NAILING | DBRITO | Approved | IVRS - Inspection 0000* |
| 01/29/2001 | STUCCO MESH | DBRITO | Approved | IVRS - Inspection 0000* |
| 05/21/2001 | PERMIT FINALED | DBRITO | Approved | |
| 05/21/2001 | MECHANICAL - FINAL | DBRITO | Approved | IVRS - Inspection 0000* |
| 05/21/2001 | PLUMBING - FINAL | DBRITO | Approved | IVRS - Inspection 0000* |
| 05/21/2001 | ELECTRIC - FINAL | DBRITO | Approved | IVRS - Inspection 0000* |
| 05/21/2001 | BUILDING - FINAL | DBRITO | Approved | IVRS - Inspection 0000* |
| 05/21/2001 | U VALUE FOR WINDOW | DBRITO | Approved | IVRS - Inspection 0000* |