Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T00CM03459
Permit Details
Apply Date:
07/11/2000
Applicant:
ACUNA RUBEN R & IMELDA V JT/RS
Description:
ADDITION:FAMILY ROOM & DINING
Permit Reviews
Permit Number - T00CM03459
Permit Status: Final
Permit Description: ADDITION:FAMILY ROOM & DINING
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/30/2004 | REVISION | 01/30/2004 | COMPLETED |
| 02/06/2004 | REVISION | 02/06/2004 | COMPLETED |
| 04/02/2003 | REVISION | 04/11/2003 | COMPLETED |
| 07/11/2000 | RESIDENTIAL BLDG/ZONING/FLOOD | 08/09/2000 | COMPLETED |
| 08/21/2000 | REVISION | 02/05/2001 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T00CM03459
Permit Status: Final
Permit Description: ADDITION:FAMILY ROOM & DINING
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 07/11/2000 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T00CM03459
Permit Description: ADDITION:FAMILY ROOM & DINING
Total Completed Inspections - 17
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/18/2000 | PLUMBING - YARD WTR LINE/TEST | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 09/18/2000 | PLUMBING - ROUGH, SOIL | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 09/18/2000 | BUILDING PRE-SLAB | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 09/18/2000 | EXCAVATION/LAYOUT REBAR & ZON | AQUIROZ | Approved | IVRS - Inspection 0000* |
| 09/16/2002 | ELECTRIC - INTERMEDIATE | MTESTER | Approved | IVRS - Inspection 0000*CALL FOR INTERMEDIATE ELECT. WHEN ALL WALLS. 2.) ARE COMPLETED ROOF FRAMING IS ON AND BEFORE INSTALLING SHEETROCK. |
| 03/27/2003 | REINFORCED MASONRY PRE-GROUT | ROHAVER | Approved | IVRS - Inspection 0000*/ 1) A PILLAR/CMU AT REAR PORCH |
| 04/14/2003 | EXT METAL CLIPS/EXT SHEATHING | ROHAVER | Approved | IVRS - Inspection 0000* |
| 10/10/2003 | MECHANICAL - FINAL | EDURAZO | Approved | IVRS - Inspection 0000* |
| 12/30/2003 | FRAMING | ROHAVER | Approved | IVRS - Inspection 0999* |
| 12/30/2003 | ROOF NAILING | ROHAVER | Approved | IVRS - Inspection 0999*/ 1) INSTALL H2.5'S PORCH RAFTERS TO BEAM AND PLATES 2) INSTALL NAILS PORCH BEAM ANCHORS 3) 2" CLEARANCE WOOD FRAMING TO FIREPLACE 4) INSTALL DOUBLE RAFTER, DOUBLE HEADERS AROUND FIREPLACE WITH APPROVED HANGERS 5) INSTALL H2.5'S RAFTERS TO PLATES 6) INSTALL APPROVED HANGERS RAFTERS TO BEAMS AND LEDGERS 7) INSTALL LAG BOLTS THROUGH 2 X LEDGERS IN TO BEAM 8) INSTALL POSITIVE CONNECTION 2 X 8 RAFTERS AT FRONT WINDOW AREA 9) INSTALL APPROVED ANCHOR BEAMS TO MASONRY 10) INSTALL H2.5'S INTERIOR BEARING WALL TOP AND BOTTOM STUDS TO PLATES 11) MAINTAIN MINIMUM 1/8" GAP ROOF 12) STRAP ALL HEADERS AT BEARING 13) ROOF SHEATHING NAILS SET TO DEEP; RENAIL ALL ROOF SHEATHING 14) INSTALL ALL MASONRY ANCHORS TO FRAMING AFTER ALL CORRECTIONS COMPLETE 15) INSTALL BOLTS AND STRAPS NEW PARAPET WALL TO EXISTING 16) STOPPED INSPECTION COMPLETE ALL TRADES 17) RECALL WHEN COMPLETED |
| 04/26/2005 | MECHANICAL - INTERMEDIATE | FGREER | Approved | IVRS - Inspection :* |
| 04/26/2005 | PLUMBING - INTERMEDIATE | FGREER | Approved | IVRS - Inspection :* |
| 05/16/2005 | SHEET ROCK NAILING | FGREER | Approved | IVRS - Inspection :* |
| 10/03/2005 | PLUMBING - FINAL | FVALENCI | Approved | IVRS - Inspection :* |
| 10/03/2005 | ELECTRIC - FINAL | FVALENCI | Approved | IVRS - Inspection :* |
| 10/03/2005 | BUILDING - FINAL | FVALENCI | Approved | IVRS - Inspection :* |
| 10/04/2005 | PERMIT FINALED | JWEATHER | Approved |