Permit: T00CM03459

Parcel: 132161330


Addresses:

4814 S CHERRY AV


Inspection Status: Approved

Inspection History: ROOF NAILING

Permit Number - T00CM03459

Inspection Description - ROOF NAILING

Inspection Status - Approved

Date Description Inspector Results Comments
02/09/2004 ROOF NAILING Approved IVRS - Inspection 0000*
02/04/2004 ROOF NAILING Partial Approval IVRS - Inspection 0000*
12/30/2003 ROOF NAILING Denied IVRS - Inspection 0999*/ 1) INSTALL H2.5'S PORCH RAFTERS TO BEAM AND PLATES 2) INSTALL NAILS PORCH BEAM ANCHORS 3) 2" CLEARANCE WOOD FRAMING TO FIREPLACE 4) INSTALL DOUBLE RAFTER, DOUBLE HEADERS AROUND FIREPLACE WITH APPROVED HANGERS 5) INSTALL H2.5'S RAFTERS TO PLATES 6) INSTALL APPROVED HANGERS RAFTERS TO BEAMS AND LEDGERS 7) INSTALL LAG BOLTS THROUGH 2 X LEDGERS IN TO BEAM 8) INSTALL POSITIVE CONNECTION 2 X 8 RAFTERS AT FRONT WINDOW AREA 9) INSTALL APPROVED ANCHOR BEAMS TO MASONRY 10) INSTALL H2.5'S INTERIOR BEARING WALL TOP AND BOTTOM STUDS TO PLATES 11) MAINTAIN MINIMUM 1/8" GAP ROOF 12) STRAP ALL HEADERS AT BEARING 13) ROOF SHEATHING NAILS SET TO DEEP; RENAIL ALL ROOF SHEATHING 14) INSTALL ALL MASONRY ANCHORS TO FRAMING AFTER ALL CORRECTIONS COMPLETE 15) INSTALL BOLTS AND STRAPS NEW PARAPET WALL TO EXISTING 16) STOPPED INSPECTION COMPLETE ALL TRADES 17) RECALL WHEN COMPLETED