Permit Details

Status:
Final
Type:
SINGLE FAMILY ADDITION
Address:
570 S 9TH AV
Address NEW:
570 S 9TH AV
Apply Date:
02/25/2000
Applicant:
MORA JESUS & METHERELL EMMA JT/R
Description:
ADDITION:LIVING ROOM

Permit Reviews

Permit Number - T00CM00906
Permit Status: Final
Permit Description: ADDITION:LIVING ROOM
Start Date Submittal Complete Date Status  
09/13/2000 RESUBMITTAL 09/21/2000 COMPLETED Review Details
10/17/2001 REVISION 10/17/2001 COMPLETED Review Details

Completed Inspections

Permit Status: Final
Permit Number: T00CM00906
Permit Description: ADDITION:LIVING ROOM
Total Completed Inspections - 21
Date Description Inspector Results Comments
11/06/2000 ELECTRIC - TEMPORARY SERVICE AQUIROZ Approved IVRS - Inspection 0000*
11/06/2000 ELECTRIC - CABLE DROP AQUIROZ Approved IVRS - Inspection 0000*
11/06/2000 ELECTRIC - UFER AQUIROZ Approved IVRS - Inspection 0000*
11/21/2000 PLUMBING - INTERMEDIATE DBRITO Approved IVRS - Inspection 0999*
12/28/2000 PLUMBING - ROUGH, SOIL AQUIROZ Approved IVRS - Inspection 0999*/PLUMBING NOT TO PLAN CORRECT AND RECALL.
01/22/2001 STEM WALL/RETAINING WALL AQUIROZ Approved IVRS - Inspection 0000*
05/09/2001 REINFORCED MASONRY PRE-GROUT FGREER Approved IVRS - Inspection 0000*
09/21/2001 PLUMBING - GAS PRESSURE TEST EDURAZO Approved IVRS - Inspection 0999*
09/21/2001 FRAMING EDURAZO Approved IVRS - Inspection 0999*/ 1) LOWER COLLAR TIES TO 1/3 SPAN 2) DOUBLE 2 X 10'S CUT/RIPPED MUST BE FULL 2-2 X 10'S 3) EM CENTER LINE NOT ALLOWED IN CONDUIT 4) RAFTER OVER SPANNED SOME 27" ON CENTER 5) BLOCK 3 SIDES AIR GRILLS 6) ACCESS TO AIR HANDLER SHALL NOT BE OBSTRUCTED 7) NEED APPROVAL ON AIR HANDLER DECK 8) DOUBLE 2 X 10 SHALL NOT BE SPLICED 9) 2" CLEARANCE REQUIRED FROM COMBUSTIBLE AT FIREPLACE CHIMNEY
09/28/2001 MECHANICAL - INTERMEDIATE EDURAZO Approved
10/10/2001 ELECTRIC - INTERMEDIATE AQUIROZ Approved IVRS - Inspection 0999*/ 1) NEED APPROVAL IN AIR HANDLER DECK PRIOR TO THESE INSPECTION
01/24/2002 ROOF NAILING AQUIROZ Approved IVRS - Inspection 0000*
02/20/2002 SHEET ROCK NAILING MTESTER Approved IVRS - Inspection 0000*
02/21/2002 PLUMBING - YARD WTR LINE/TEST MTESTER Approved IVRS - Inspection 0000*
03/18/2002 PLUMBING - FINAL MTESTER Approved IVRS - Inspection 0000*
03/18/2002 PLUMBING - SEWER HCS CONNECT MTESTER Approved IVRS - Inspection 0000*
03/18/2002 ELECTRIC - FINAL MTESTER Approved IVRS - Inspection 0000*
03/19/2002 U VALUE FOR WINDOW MTESTER Approved IVRS - Inspection 0000*
03/20/2002 PERMIT FINALED MTESTER Approved
03/20/2002 MECHANICAL - FINAL MTESTER Approved IVRS - Inspection 0000*
03/20/2002 BUILDING - FINAL MTESTER Approved IVRS - Inspection 0000*