Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T00CM00906
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/24/2002 | FRAMING | Approved | IVRS - Inspection 0000* | |
01/23/2002 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) NEED FRAMING FOR CEILING FAN | |
09/21/2001 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) LOWER COLLAR TIES TO 1/3 SPAN 2) DOUBLE 2 X 10'S CUT/RIPPED MUST BE FULL 2-2 X 10'S 3) EM CENTER LINE NOT ALLOWED IN CONDUIT 4) RAFTER OVER SPANNED SOME 27" ON CENTER 5) BLOCK 3 SIDES AIR GRILLS 6) ACCESS TO AIR HANDLER SHALL NOT BE OBSTRUCTED 7) NEED APPROVAL ON AIR HANDLER DECK 8) DOUBLE 2 X 10 SHALL NOT BE SPLICED 9) 2" CLEARANCE REQUIRED FROM COMBUSTIBLE AT FIREPLACE CHIMNEY |