Permit: T00CM00906

Parcel: 117144320


Addresses:

570 S 9TH AV

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/24/2002 FRAMING Approved IVRS - Inspection 0000*
01/23/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) NEED FRAMING FOR CEILING FAN
09/21/2001 FRAMING Denied IVRS - Inspection 0999*/ 1) LOWER COLLAR TIES TO 1/3 SPAN 2) DOUBLE 2 X 10'S CUT/RIPPED MUST BE FULL 2-2 X 10'S 3) EM CENTER LINE NOT ALLOWED IN CONDUIT 4) RAFTER OVER SPANNED SOME 27" ON CENTER 5) BLOCK 3 SIDES AIR GRILLS 6) ACCESS TO AIR HANDLER SHALL NOT BE OBSTRUCTED 7) NEED APPROVAL ON AIR HANDLER DECK 8) DOUBLE 2 X 10 SHALL NOT BE SPLICED 9) 2" CLEARANCE REQUIRED FROM COMBUSTIBLE AT FIREPLACE CHIMNEY