Permit: T00CM00906
Permit Details
Apply Date:
02/25/2000
Applicant:
MORA JESUS & METHERELL EMMA JT/R
Description:
ADDITION:LIVING ROOM
Permit Reviews
Permit Number - T00CM00906
Permit Status: Final
Permit Description: ADDITION:LIVING ROOM
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
09/13/2000 | RESUBMITTAL | 09/21/2000 | COMPLETED |
10/17/2001 | REVISION | 10/17/2001 | COMPLETED |
Completed Inspections
Permit Status: Final
Permit Number: T00CM00906
Permit Description: ADDITION:LIVING ROOM
Total Completed Inspections - 21
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/06/2000 | ELECTRIC - TEMPORARY SERVICE | AQUIROZ | Approved | IVRS - Inspection 0000* |
11/06/2000 | ELECTRIC - CABLE DROP | AQUIROZ | Approved | IVRS - Inspection 0000* |
11/06/2000 | ELECTRIC - UFER | AQUIROZ | Approved | IVRS - Inspection 0000* |
11/21/2000 | PLUMBING - INTERMEDIATE | DBRITO | Approved | IVRS - Inspection 0999* |
12/28/2000 | PLUMBING - ROUGH, SOIL | AQUIROZ | Approved | IVRS - Inspection 0999*/PLUMBING NOT TO PLAN CORRECT AND RECALL. |
01/22/2001 | STEM WALL/RETAINING WALL | AQUIROZ | Approved | IVRS - Inspection 0000* |
05/09/2001 | REINFORCED MASONRY PRE-GROUT | FGREER | Approved | IVRS - Inspection 0000* |
09/21/2001 | PLUMBING - GAS PRESSURE TEST | EDURAZO | Approved | IVRS - Inspection 0999* |
09/21/2001 | FRAMING | EDURAZO | Approved | IVRS - Inspection 0999*/ 1) LOWER COLLAR TIES TO 1/3 SPAN 2) DOUBLE 2 X 10'S CUT/RIPPED MUST BE FULL 2-2 X 10'S 3) EM CENTER LINE NOT ALLOWED IN CONDUIT 4) RAFTER OVER SPANNED SOME 27" ON CENTER 5) BLOCK 3 SIDES AIR GRILLS 6) ACCESS TO AIR HANDLER SHALL NOT BE OBSTRUCTED 7) NEED APPROVAL ON AIR HANDLER DECK 8) DOUBLE 2 X 10 SHALL NOT BE SPLICED 9) 2" CLEARANCE REQUIRED FROM COMBUSTIBLE AT FIREPLACE CHIMNEY |
09/28/2001 | MECHANICAL - INTERMEDIATE | EDURAZO | Approved | |
10/10/2001 | ELECTRIC - INTERMEDIATE | AQUIROZ | Approved | IVRS - Inspection 0999*/ 1) NEED APPROVAL IN AIR HANDLER DECK PRIOR TO THESE INSPECTION |
01/24/2002 | ROOF NAILING | AQUIROZ | Approved | IVRS - Inspection 0000* |
02/20/2002 | SHEET ROCK NAILING | MTESTER | Approved | IVRS - Inspection 0000* |
02/21/2002 | PLUMBING - YARD WTR LINE/TEST | MTESTER | Approved | IVRS - Inspection 0000* |
03/18/2002 | PLUMBING - FINAL | MTESTER | Approved | IVRS - Inspection 0000* |
03/18/2002 | PLUMBING - SEWER HCS CONNECT | MTESTER | Approved | IVRS - Inspection 0000* |
03/18/2002 | ELECTRIC - FINAL | MTESTER | Approved | IVRS - Inspection 0000* |
03/19/2002 | U VALUE FOR WINDOW | MTESTER | Approved | IVRS - Inspection 0000* |
03/20/2002 | PERMIT FINALED | MTESTER | Approved | |
03/20/2002 | MECHANICAL - FINAL | MTESTER | Approved | IVRS - Inspection 0000* |
03/20/2002 | BUILDING - FINAL | MTESTER | Approved | IVRS - Inspection 0000* |