Permit Details

Status:
Final
Type:
SINGLE FAMILY NEW
Address:
925 N NATACHEE
Address NEW:
925 N NATACHEE
Apply Date:
02/18/2000
Applicant:
MONTANO DANIEL
Description:
SFR

Permit Reviews

Permit Number - T00CM00805
Permit Status: Final
Permit Description: SFR
Start Date Submittal Complete Date Status  
07/20/2000 REVISION - RESUBMITTAL 01/30/2001 COMPLETED Review Details

Completed Inspections

Permit Status: Final
Permit Number: T00CM00805
Permit Description: SFR
Total Completed Inspections - 16
Date Description Inspector Results Comments
05/23/2000 ELECTRIC - UFER RFREIDIN Approved DENIED
05/23/2000 ELECTRIC - UFER RFREIDIN Approved ADDTL COMMS - NEC 250-94 REQA A 1/0 GROUNDING ELECTRODS CONDUCTOR SEE NOTES BELOW TABLE
07/25/2000 EXCAVATION/LAYOUT REBAR & ZON RFREIDIN Approved 1ST FLOOR WEST FTGS (PERIMETER)
08/04/2000 PLUMBING - ROUGH, SOIL RFREIDIN Approved IVRS - Inspection 0000*/1ST FLOOR GROUND LEVEL
08/11/2000 BUILDING PRE-SLAB RFREIDIN Approved IVRS - Inspection 0000*/MAIN FLR. WEST UPPER LEVEL
11/16/2000 ROOF NAILING RFREIDIN Approved IVRS - Inspection 0000*/ROOF FRAMING ITEMS: 1. CONTINOUS BEARING V-TRUSSES, UPLIFT OR NAILING HARDWARE PER SHOP DRAWINGS 2. X-BRACING-PER SHOP DRAWINGS. 3. LATERAL BRACING PER SHOP DRAWINGS. 4. 3 PT. BEARING TRUSSES (SEE SHOP DRAWINGS HIGHLIGHTED). 5. PURLIN NAILING AND DESIGN FOR TRUSS TILE LOAD. 6. HEADER SIZES. 7. SUPPORT PLYWOOD EDGES, HIP SIDES TO VAULTED ROOF. 8. BRACE PONY WALLS FRONT AND BACK. 9. BEAM HARDWARE INTERIOR BEARING. 10. ALL GIRDER TO TRUSS HANGER SIZES. 11. SOME ROOF DECK AT EAVES NOT INSTALLED. 12. TURRET FRAMING AND DECK NOT COMPLETE. 13. P.A. STRAPS AT 1ST. FLOOR LEDGERS 14. DBL STUD GIRDER TRUSS BEARIN. 15. NOTE: INTERMEDIATE PLUMBING?
01/17/2001 MECHANICAL - INTERMEDIATE BSTEVENS Approved IVRS - Inspection 0000*
01/17/2001 U VALUE FOR WINDOW BSTEVENS Approved IVRS - Inspection 0000*
03/06/2001 STUCCO MESH RFREIDIN Approved IVRS - Inspection 0000*
03/20/2001 FRAMING RFREIDIN Approved IVRS - Inspection 0000*
05/02/2001 SHEET ROCK NAILING RFREIDIN Approved IVRS - Inspection 0000*/ GARAGE FURN ROOM NEED RETUN PLATFORM 18" ABOVE LOWER GARAGE FF (NOT CURB STOP) NEED COMB/RELIEF DUCT HI/LOW CHECK SIZE OF H20 HEATER FLUE REQ 1/4 PITCH FOR FT
09/05/2001 MECHANICAL - FINAL RFREIDIN Approved IVRS - Inspection 0000*
09/05/2001 PLUMBING - FINAL RFREIDIN Approved IVRS - Inspection 0000*
09/05/2001 ELECTRIC - FINAL RFREIDIN Approved IVRS - Inspection 0000*
09/05/2001 BUILDING - FINAL RFREIDIN Approved IVRS - Inspection 0000*/ 1) INSTALL C.O. CAPS 2) NEED LOX AT ALL CONDUCTORS SERVICE EQUIPMENT 3) 30 AMP VACUMN CIRCUIT, USE GE TYPE BREAKER 4) NEED HANDRAIL AT REAR STAIR 5) NEED SINGLE OUTLET RECERT AT WATER SOFTNER 6) PLUG AT SOIL LINES (SEWER GAS) 7) OUTLET COMBUSTION AIR FOR FURNACE/ WATER HEATER GARAGE 8) GAS TAG GIVEN FOR CONSTRUCTION
03/05/2002 PERMIT FINALED RFREIDIN Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW