Inspection Status: Partial Approval
Inspection History: ROOF NAILING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/16/2000 |
ROOF NAILING |
|
Partial Approval |
IVRS - Inspection 0000*/ROOF FRAMING ITEMS: 1. CONTINOUS BEARING V-TRUSSES, UPLIFT OR NAILING HARDWARE PER SHOP DRAWINGS 2. X-BRACING-PER SHOP DRAWINGS. 3. LATERAL BRACING PER SHOP DRAWINGS. 4. 3 PT. BEARING TRUSSES (SEE SHOP DRAWINGS HIGHLIGHTED). 5. PURLIN NAILING AND DESIGN FOR TRUSS TILE LOAD. 6. HEADER SIZES. 7. SUPPORT PLYWOOD EDGES, HIP SIDES TO VAULTED ROOF. 8. BRACE PONY WALLS FRONT AND BACK. 9. BEAM HARDWARE INTERIOR BEARING. 10. ALL GIRDER TO TRUSS HANGER SIZES. 11. SOME ROOF DECK AT EAVES NOT INSTALLED. 12. TURRET FRAMING AND DECK NOT COMPLETE. 13. P.A. STRAPS AT 1ST. FLOOR LEDGERS 14. DBL STUD GIRDER TRUSS BEARIN. 15. NOTE: INTERMEDIATE PLUMBING? |
| 11/13/2000 |
ROOF NAILING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/1. PLEASE RECALL 2. NEED TRUSS SHOP DRAWINGS ON SITE FOR THIS INSPECTION. |