Permit: T00CM00182
Permit Details
Apply Date:
01/14/2000
Applicant:
STEWART KEVIN
Description:
NEW DAY CARE CENTER
Architects:
- CARNELL, WILLIAM B
Contractors:
- GILES CONSTRUCTION INC ,
Permit Reviews
Permit Number - T00CM00182
Permit Status: C of o
Permit Description: NEW DAY CARE CENTER
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/10/2001 | REVISION | 01/16/2001 | COMPLETED |
01/19/2001 | REVISION | 01/22/2001 | COMPLETED |
03/28/2001 | REVISION | 04/12/2001 | COMPLETED |
04/24/2001 | REVISION | 05/01/2001 | COMPLETED |
07/21/2000 | REVISION - RESUBMITTAL | 09/29/2000 | COMPLETED |
10/22/2001 | REVISION | 10/22/2001 | COMPLETED |
Completed Inspections
Permit Status: C of o
Permit Number: T00CM00182
Permit Description: NEW DAY CARE CENTER
Total Completed Inspections - 35
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/28/2000 | ELECTRIC - UFER | JORTA | Approved | IVRS - Inspection 0000* BUILD C UFER APPROVED |
12/04/2000 | REINFORCED MASONRY PRE-GROUT | DWITT | Approved | IVRS - Inspection 0000* |
12/04/2000 | STEM WALL/RETAINING WALL | DWITT | Approved | IVRS - Inspection 0000* TURN THE CONTINOUS STEEL INTO THE LAST GROUT CELL OF THE "POP OUTS" |
12/06/2000 | EXCAVATION/LAYOUT REBAR & ZON | DWITT | Approved | IVRS - Inspection 0000* INTERIOR COL FTGS, EXT COL, FTGS |
12/26/2000 | ELECTRIC - UNDERGROUND | RHOLLAND | Approved | IVRS - Inspection 0000* OK UNDER BUILDING 2-4, 1-2, 1- 1 1/4", 1-1" |
01/17/2001 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection 0000* WATER TEST 42" OK N/IT UNDERGROUND OK UNDERGROUND INSTALLED PER PLAN ANY CHANGES NEED TO BE OK'D AND RETESTED OK TO COVER 01/22/2001 03005 CHANGES MADE TO APPROVED PLANS CHANGES MADE OK CHANGES MADE AND APPROVED ON PLANS WATER TEST TO 42" OK OK TO BACKFILL |
01/29/2001 | BUILDING PRE-SLAB | DWITT | Approved | IVRS - Inspection 0000* |
03/06/2001 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection 0000* OK TO BACK FILL |
04/06/2001 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | ROUGH GAS IN BLDG "C" OK PRESSURE TEST OK |
04/30/2001 | ROOF NAILING | AMATHIES | Approved | IVRS - Inspection 0000* |
05/25/2001 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection 0000*PLEASE ADVISE MECH. SUB. WHEN CALLING FOR INSPECTION.OK TO COVER. |
05/25/2001 | FRAMING | DWITT | Approved | IVRS - Inspection 0000* |
06/20/2001 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection 0000* |
06/29/2001 | SHEET ROCK NAILING | DWITT | Approved | |
07/05/2001 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection 0000* |
07/25/2001 | BUILDING ABOVE CEILING | DWITT | Approved | IVRS - Inspection 0000* |
07/26/2001 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | IVRS - Inspection 0000* |
07/26/2001 | ELECTRIC - ABOVE CEILING | JORTA | Approved | IVRS - Inspection 0000*EAST PORTION O.K. REST OF CEILING IN COMPLETE. |
08/15/2001 | MECHANICAL - FINAL | CWILLIAM | Approved | 48,000 BTUH COOL. 120 M HEAT. MAX FUSE SIZE 50 AMPS. |
08/15/2001 | BUILDING - TEMP POWER FOR TEST | AMATHIES | Approved | IVRS - Inspection 0000*30 DAYS FROM 8-16-01 |
08/16/2001 | MECHANICAL - TEMP PWR FOR TEST | CWILLIAM | Approved | IVRS - Inspection 0000* |
08/16/2001 | PLUMBING - TEMP POWER FOR TEST | RMYERS | Approved | IVRS - Inspection 0000*1.) APPROVED TEMP POWER PENDING ANY OTHER INSPECTION. |
08/16/2001 | ELECTRIC - TEMP POWER FOR TEST | JORTA | Approved | IVRS - Inspection 0000*MUST HAVE LETTER SIGNED DATED WITH LETTERHEAD. CERTIFYING THAT 1065 SERVICE EQUIPMENT HAS ALL BEEN TORQUED PER MANFACTURE SPECIFICATION. |
09/04/2001 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection 0000*OK TEMP C/O W NO KIDS INSIDE PENDING APPROVAL BY STEVE LONG. LOOKING FOR TEMP C/O NO KIDS. |
09/06/2001 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection 0000* |
10/11/2001 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection 0000*1.) ALL CORRECTIONS MADE OK 2.) OK FOR C OF O PENDING ANYOTHER INSPECTION 3.) UCC LEFT AT METER. |
10/30/2001 | ELECTRIC - FINAL | JORTA | Approved | IVRS - Inspection 0000*FOR BUILD C APPROVED. |
11/29/2001 | ENGINEERING - FINAL | DROBERTS | Approved | AS NOTED PREVIOUSLY |
03/29/2002 | PERMIT FINALED | LHANLY | Approved | |
03/29/2002 | FIRE SPKLR - OH PIPING & HYDRO | LTHOMAS | Approved | |
03/29/2002 | FIRE SPKLR - UG PIPING FLUSH | LTHOMAS | Approved | |
03/29/2002 | FIRE SPKLR - UG, PIPING, HYDRO | LTHOMAS | Approved | |
03/29/2002 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | |
03/29/2002 | U VALUE FOR WINDOW | LHANLY | Approved | |
03/29/2002 | EXT METAL CLIPS/EXT SHEATHING | LHANLY | Approved |