Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
COMMERCIAL OTHER
Address NEW:
3180 N CAMPBELL AV
Apply Date:
05/24/2000
Applicant:
STANTEC CONSULTING INC
Description:
GRADING:2,070CY CUT & 530CY FILL
Contractors:
  • EVERGREEN BUILDERS INC ,

Permit Reviews

Permit Number - T00BU01603
Permit Status: Final
Permit Description: GRADING:2,070CY CUT & 530CY FILL
Start Date Submittal Complete Date Status  
07/20/2000 REVISION - RESUBMITTAL 07/27/2000 COMPLETED Review Details
07/27/2000 GRADING 08/17/2000 COMPLETED Review Details
08/17/2000 GRADING 12/15/2000 COMPLETED Review Details

Completed Inspections

Permit Status: Final
Permit Number: T00BU01603
Permit Description: GRADING:2,070CY CUT & 530CY FILL
Total Completed Inspections - 2
Date Description Inspector Results Comments
09/04/2002 GRADING - FINAL LMAKUS Approved 1) THE WEIR OUTLET HAS NOT BEEN CONSTRUCTED PER THE APPROVED PLANS IN THE DETENTION / RETENTION BASIN. 2) THE PLACEMENT OF THE ROCK RIPRAP EROSION PROTECTION AT THE SOUTHERN INLET OF THE BASIN HAS NOT BEEN PLACED CORRECTLY. EROSION HAS BEEN NOTED IN THIS AREA AND WILL NEED TO BE REPAIRED, ADDITIONAL MATERIALS WILL NEED TO BE PLACED TO PROTECT THE AREA IN THE FUTURE. 3) SEDIMENTS FROM THE EROSION HAS CAUSED SOME BLOCKAGE OF THE STORM SEWER DRAIN LINES FROM THE SOUTHERN PARKING LOTS. REMOVE ALL OF THE SEDIMENT MATERIAL AND RE-ESTABLISH POSITIVE FLOW TO THIS LINE.
06/02/2004 PERMIT FINALED DROBERTS Approved