Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T00BU01603

Parcel: 11205052B


Addresses:

3180 N CAMPBELL AV


Inspection Status: Approved

Inspection History: GRADING - FINAL

Permit Number - T00BU01603

Inspection Description - GRADING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
06/01/2004 GRADING - FINAL Approved
09/04/2002 GRADING - FINAL Denied 1) THE WEIR OUTLET HAS NOT BEEN CONSTRUCTED PER THE APPROVED PLANS IN THE DETENTION / RETENTION BASIN. 2) THE PLACEMENT OF THE ROCK RIPRAP EROSION PROTECTION AT THE SOUTHERN INLET OF THE BASIN HAS NOT BEEN PLACED CORRECTLY. EROSION HAS BEEN NOTED IN THIS AREA AND WILL NEED TO BE REPAIRED, ADDITIONAL MATERIALS WILL NEED TO BE PLACED TO PROTECT THE AREA IN THE FUTURE. 3) SEDIMENTS FROM THE EROSION HAS CAUSED SOME BLOCKAGE OF THE STORM SEWER DRAIN LINES FROM THE SOUTHERN PARKING LOTS. REMOVE ALL OF THE SEDIMENT MATERIAL AND RE-ESTABLISH POSITIVE FLOW TO THIS LINE.