Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY ADDITION
Apply Date:
02/09/2000
Applicant:
SUNDRY BUILDERS
Description:
ADDITION:PORCH AT REAR
Contractors:
  • SUNDRY BUILDERS

Outstanding Inspections

Permit Status: Expired
Permit Number: T00BU00430
Permite Description: ADDITION:PORCH AT REAR
Total Outstanding Inspections - 5
Last Inspection Date Description Inspector Results Comments
EXCAVATION/LAYOUT REBAR & ZON N/A Not Inspected
BUILDING PRE-SLAB N/A Not Inspected
ROOF NAILING N/A Not Inspected
BUILDING - FINAL N/A Not Inspected
02/24/2000 FRAMING N/A Correction Required ADDTL COMMS - PARTIAL - PROVIDE 4-20d BOX NAILS PER STUD AT LEDGER. 30PSF(10/2) = 150 PLF AT LEDGER 30PSF(10/2) = 150 PLF AT LEDGER FRAME WALL APPEARS TO BE AT 24C.C. (2 FT. CC) 150 PLF X 2 C.C. = 3.65 NAILS. USE 4 NAILS PER STUD 82#