Permit: DP14-0233
Permit Details
Status:
Complete
Type:
Development Package
Address:
5130 N GRACIOUS CT
Address NEW:
5130 N GRACIOUS CT
Apply Date:
12/11/2014
Applicant:
Description:
GRADING ONLY
Permit Reviews
Permit Number - DP14-0233
Permit Status: Complete
Permit Description: GRADING ONLY
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/25/2015 | REVISION - GRADING | 08/12/2015 | COMPLETED |
| 12/11/2014 | GRADING | 06/25/2015 | COMPLETED |
Conditions
Permit Number - DP14-0233
Permit Status: Complete
Permit Description: GRADING ONLY
| Date | Description | Comments |
|---|---|---|
| 12/11/2014 | The following 10 conditions apply to grading permit for lot 12 (DP14-0233):1)There shall be no disturbance, and that materials and / or construction equipment may not be stockpiled or parked, outside of approved grading limits at any time. 2)All grading construction work shall conform to IBC Chapter 18, City of Tucson DS Sec.11-01, and Hillside Development Zone requirements.3)This lot is located in SCZ so 3:1(H:V) slopes is the max slope grade allowed. Any small areas of rip rapped slope shall have handplaced stone with filter fabric per HDZ requirements, unless required to have handplaced grouted rip rap or other slope protection as per geotechnical engineering report or addenda. 4)Any future wall openings shall be provided for surface drainage from yard or patio areas. 5)If grading construction is expected to last longer than the expiration date of the grading permit, contact City of Tucson Development Services Department to renew/extend the Grading Permit. If Final Grading Inspection has not been completed before the Grading Permit expires, and the permit has not been renewed, additional fees and reviews may be required.6)Call for PDSD Engineering Pre-construction meeting and other Inspections. For a PDSD Engineering Inspection, call IVR (740-6970), or schedule with a Customer Service Representative at the Planning & Development Services Department, or contact PDSD Engineering at 837-4888, or schedule inspections online at: http://www.ci.tucson.az.us/dsd/Online_Services/Online_Permits/online_permits.html 7)Any revision to the Grading Plan may require a re-submittal of a revised grading plan for review. Contact PDSD Engineering at 791-5550 to discuss changes in grading design.8)If grading construction is expected to last longer than the expiration date of the grading permit, contact PDSD to renew/extend the Grading Permit. If Final Grading Inspection has not been completed before the Grading Permit expires, and the permit has not been renewed, additional fees and reviews may be required. 9)The permitee shall notify the PDSD when the grading operation is ready for final grading inspection. Final grading approval shall not be given until all work, including installation of all erosion control measures have been completed in accordance with the approved grading plan and grading permit. 10)Any remaining assurable items shall be completed prior to release of this CofO, including, if required, handplaced rip rap with filter fabric in public slope easement within lot boundary. |
Completed Inspections
Permit Status: Complete
Permit Number: DP14-0233
Permit Description: GRADING ONLY
Total Completed Inspections - 7
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/05/2015 | PDSD Engineering Division Pre-Construction SITE | Passed | {Activity date: 02/05/2015; Status: Approved; Inspector: MRUSSO; Comment: Entered by DROBERT5 - 1) INSTALL SEDIMENT CONTROLS PER PLAN, PER SITE SPECIFICS AND PER INSPECTION RECOMMENDATIONS. 2) NO NPPO REQUIREMENTS FOR LOT 3) MAY NEED TO MARK GRADING LIMIT TO PREVENT ENCROACHMENT INTO NATURAL OPEN SPACE AREA 4) CALL FOR INSPECTION ONCE CONTROLS ARE IN PLACE} |
|
| 06/25/2015 | PDSD Site/Engineering Division - Landscaping | Passed | {Activity date: 06/25/2015; Status: Approved; Inspector: MRUSSO; Comment: Entered by DROBERT5 - } ; {Activity date: 02/12/2015; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - NO SIGNIFICANT CHANGES AND/OR CONCERNS} ; {Activity date: 02/05/2015; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - NO NPPO REQUIREMENTS PER PLAN} | |
| 06/25/2015 | ENGR Engineering Final | Passed | {Activity date: 06/25/2015; Status: Approved; Inspector: MRUSSO; Comment: Entered by DROBERT5 - } | |
| 06/25/2015 | SITE - Stormwater Follow-up | Passed | {Activity date: 06/25/2015; Status: Approved; Inspector: MRUSSO; Comment: Entered by DROBERT5 - } ; {Activity date: 05/15/2015; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - NO SIGNIFICANT STORM WATER CONCERNS AT THIS TIME} ; {Activity date: 05/06/2015; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - NO CHANGES AND/OR CONCERNS AT THIS TIME} ; {Activity date: 04/16/2015; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - NO SGINIFICANT STORM WATER CONCERNS AT THIS TIME} ; {Activity date: 03/16/2015; Status: Continued; Inspector: MRUSSO; Comment: Entered by ARUIZ1 - 1. SWEEP UP TANKED SOIL PFF ADJACENT ROADWAY 2. ENSURE YOU PERFORM STORM WATER SELF INSPECTION AND DOCMENT THEM 3. CLEAN UP AND DISPOSE OF CONCRETE/MATERIALS WASH OUT 4. MAINTAIN SEDIMENT CONTROL THROUGHT CONSTRUCTION} ; {Activity date: 04/07/2015; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - 1) NO SIGNIFICANT STORM WATER CONCERNS AT THIS TIME 2) SWEEP UP TRACKED SOIL AS NEEDED} ; {Activity date: 03/09/2015; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - NO SIGNIFICANT STORM WATER CONCERNS AT THIS TIME} ; {Activity date: 02/26/2015; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - NO STORM WATER COCNERNS AT THIS TIME} ; {Activity date: 02/12/2015; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - NO SIGNIFICANT STORM WATER COCNERNS AT THIS TIME} |
|
| 06/25/2015 | ENGR Grading Final | Passed | {Activity date: 06/25/2015; Status: Approved; Inspector: MRUSSO; Comment: Entered by DROBERT5 - } ; {Activity date: 05/06/2015; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - NO CHANGES AND/OR CONCERNS AT THIS TIME} ; {Activity date: 04/22/2015; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - NO CHANGES AND/OR CONCERNS AT THIS TIME} ; {Activity date: 02/26/2015; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - CALL FOR INSPECTION FOR ANY CHANGES FROM THE ORIGINAL PLAN.} | |
| 06/25/2015 | SITE - Stormwater Final Inspection | Passed | {Activity date: 06/25/2015; Status: Approved; Inspector: MRUSSO; Comment: Entered by DROBERT5 - } | |
| 06/25/2015 | SITE - Stormwater Setup and Controls | Passed | {Activity date: 06/25/2015; Status: Approved; Inspector: MRUSSO; Comment: Entered by DROBERT5 - } |