Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: DP14-0056
Permit Details
Apply Date:
04/11/2014
Applicant:
Description:
SITE/GRADING/SWPPP
Permit Reviews
Permit Number - DP14-0056
Permit Status: Complete
Permit Description: SITE/GRADING/SWPPP
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/20/2017 | REVISION - SITE | 01/23/2017 | ACTIVE |
| 04/11/2014 | DEV PKG - OK TO SUBMIT | 05/09/2014 | COMPLETED |
| 05/09/2014 | SITE and/or GRADING | 06/11/2014 | COMPLETED |
| 05/21/2015 | REVISION - SITE | 05/22/2015 | COMPLETED |
| 10/15/2014 | RESUB - SITE/GRADING ALL | 11/14/2014 | COMPLETED |
| 11/18/2014 | RESUB - SITE/GRADING ALL | 11/19/2014 | COMPLETED |
| 12/27/2016 | REVISION - - 1ST | 01/05/2017 | COMPLETED |
Conditions
Permit Number - DP14-0056
Permit Status: Complete
Permit Description: SITE/GRADING/SWPPP
| Date | Description | Comments |
|---|---|---|
| 11/19/2014 | The following 11 conditions apply to this grading permit DP14-0056:1)Call for Pre-construction meeting. For a PDSD Engineering Inspection, call IVR (740-6970), or schedule with a Customer Service Representative at the Planning & Development Services Department - Angie 837-4917, or contact PDSD Engineering at 837-4888, or schedule inspections online at: http://www.ci.tucson.az.us/dsd/Online_Services/Online_Permits/online_permits.html 2)Copy of approved plan/permit DP14-0056 shall be kept at site at all times until final grading approval.3)These sets of plans act as the approved grading plan for Brown/Rita Ranch Lot 42 sealed by Jeff Stanley P.E. 4)There shall be no disturbance outside of the disturbance/grading limits as shown on approved grading plans. 5)PDSD Inspector shall be called to inspect special grading, such as drainage, outlet when under construction. 6)Contact Permits and Codes (837-6606) for any questions regarding City of Tucson right-of-way permit requirements. 7)If grading construction is expected to last longer than the expiration date of the grading permit, contact PDSD to renew/extend the Grading Permit. If Final Grading Inspection has not been completed before the Grading Permit expires, and the permit has not been renewed, additional fees and reviews may be required.8)Revisions to the design must be discussed with a Civil Engineer at the City of Tucson Planning & Development Services Department Engineering Division, prior to any construction activity, to determine whether additional details, calculations, drainage report, or a revised grading plan is needed, or, whether changes may be provided on as-builts. All work completed without approval is subject to Stop Work Order. 9)Permittee shall notify the PDSD when the grading operation is ready for final grading inspection. Final grading approval shall not be given until all work, including installation of all drainage improvements and their permanent protective devices, and all permanent erosion control measures have been completed in accordance with the approved grading plan and grading permit, and all conditions of permit are completed. Any revegetated areas shall require Landscaping approval of established vegetation prior to Final Grading Approval. Any other exposed areas that are not reseeded shall be covered in gravel, unless other material is proposed, reviewed, and accepted by City of Tucson.10)Temporary erosion and sediment control devices shall be placed at locations where stormwater runoff exits grading limits to prevent debris, construction silt, and/or chemicals from entering streets or any drainage ways. Any interim erosion and sediment controls that are installed should be maintained, per approved SWPPP plans or per EOR, at downstream areas of disturbance limits. These interim controls must be removed after all permanent controls have been established.11)Final Revised Grading Plan (as-builts) is required to be submitted prior to final Grading Inspection. As-builts should include as-built elevations for finished pad grades, outlet area, and other areas as deemed needed by surveyor. |
Completed Inspections
Permit Status: Complete
Permit Number: DP14-0056
Permit Description: SITE/GRADING/SWPPP
Total Completed Inspections - 7
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/15/2015 | PDSD Engineering Division Pre-Construction SITE | Passed | {Activity date: 01/15/2015; Status: Approved; Inspector: MRUSSO; Comment: Entered by DROBERT5 - 1) PROJECT IS GREATER THAN 1 ACRE AND IS UNDER A STORM WATER PERMIT. 2) CONTRACTOR HAS FILED A NOTICE OF INTENT WITH ADEQ 3) INSTALL SEDIMENT CONTROLS PER YOU APPROVED STORM WATER PLAN AND PER MY INSPECTION. 4) CALL FOR RE-INSPECTION WHEN CONTROLS HAVE BEEN INSTALLED. 5) ENSURE STORM WATER SELF INSPECTION ARE PERFORMED AND DOCUMENTED. 6) INSTALL A STABILIZED CONSTRUCTION ENTRANCE AND CONCRETE WASH OUT PER YOU PLAN. 7) WILL VERIFY NPPO} |
|
| 02/17/2017 | PDSD Site/Engineering Division - Landscaping | Passed | {Activity date: 02/17/2017; Status: Approved; Inspector: MRUSSO; Comment: Entered by DROBERT5 - } ; {Activity date: 03/30/2016; Status: Cancelled; Inspector: IVR USER; Comment: Entered by IVR USER - IVRS - RI canceled} | |
| 02/17/2017 | ENGR Engineering Final | Passed | {Activity date: 02/17/2017; Status: Approved; Inspector: MRUSSO; Comment: Entered by DROBERT5 - } | |
| 02/17/2017 | SITE - Stormwater Follow-up | Passed | {Activity date: 02/17/2017; Status: Approved; Inspector: MRUSSO; Comment: Entered by DROBERT5 - } ; {Activity date: 03/31/2016; Status: Violation; Inspector: MRUSSO; Comment: Entered by MRUSSO1 - SITE IN NON-COMPLIANCE WITH SWPPP} | |
| 02/17/2017 | ENGR Grading Final | Passed | {Activity date: 02/17/2017; Status: Approved; Inspector: MRUSSO; Comment: Entered by DROBERT5 - } | |
| 02/17/2017 | SITE - Stormwater Final Inspection | Passed | {Activity date: 02/17/2017; Status: Approved; Inspector: MRUSSO; Comment: Entered by DROBERT5 - } | |
| 02/17/2017 | SITE - Stormwater Setup and Controls | Passed | {Activity date: 02/17/2017; Status: Approved; Inspector: MRUSSO; Comment: Entered by DROBERT5 - } ; {Activity date: 01/15/2015; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - } |