Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: DP13-0179
Permit Details
Apply Date:
09/10/2013
Applicant:
Description:
N/A
Permit Reviews
Permit Number - DP13-0179
Permit Status: Complete
Permit Description:
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
09/10/2013 | GRADING | 09/10/2013 | COMPLETED |
Completed Inspections
Permit Status: Complete
Permit Number: DP13-0179
Permit Description:
Total Completed Inspections - 7
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/12/2013 | PDSD Engineering Division Pre-Construction SITE | Passed | {Activity date: 09/12/2013; Status: Approved; Inspector: RLEDONNE; Comment: Entered by RLEDONN1 - WORKING ON LANDSCAPING.} | |
04/22/2014 | PDSD Site/Engineering Division - Landscaping | Passed | {Activity date: 04/22/2014; Status: Approved; Inspector: DROBERTS; Comment: Entered by DROBERT5 - } | |
04/22/2014 | SITE - Stormwater Follow-up | Passed | {Activity date: 04/22/2014; Status: Approved; Inspector: DROBERTS; Comment: Entered by DROBERT5 - } | |
04/22/2014 | SITE - Stormwater Final Inspection | Passed | {Activity date: 04/22/2014; Status: Approved; Inspector: DROBERTS; Comment: Entered by DROBERT5 - } | |
04/22/2014 | SITE - Stormwater Setup and Controls | Passed | {Activity date: 04/22/2014; Status: Approved; Inspector: DROBERTS; Comment: Entered by DROBERT5 - } | |
04/24/2014 | ENGR Engineering Final | Passed | {Activity date: 04/24/2014; Status: Approved; Inspector: DROBERTS; Comment: Entered by DROBERT5 - GRADING IS APPROVED AT THIS TIME. I HAVE NOTED THAT THERE IS NO FILTER FABRIC UNDERNEATH THE ROCK RIP RAP MATERIAL, AND NO CONCRETE LINED AREASAT THE LOCATIONS WHERE ALL OF THE DRAINAGE FROM THE ROOF DRAINAGE IS CONCENTRATED TO. THE LACK OF THESE ITEMS CAN BE A MAINTENANCE ISSUE IN THE FUTURE AFTER THE LOCAL RAINS. IF THERE IS ANY MATERIAL WASHED AWAY DURING A STORM IT WILL NEED TO BE REMOVED FROM THE NUOS AREA AND PLACED BACK INTO THEORIGINAL LOCATION.} | |
04/24/2014 | ENGR Grading Final | Passed | {Activity date: 04/24/2014; Status: Approved; Inspector: DROBERTS; Comment: Entered by DROBERT5 - } |