Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: DP12-0041
Permit Details
Apply Date:
03/22/2012
Applicant:
Description:
AREVA E IRVINGTON
Permit Reviews
Permit Number - DP12-0041
Permit Status: Complete
Permit Description: AREVA E IRVINGTON
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
03/22/2012 | DEV PKG - OK TO SUBMIT (SITE) | 03/22/2012 | COMPLETED |
03/22/2012 | SITE and/or GRADING | 06/01/2012 | COMPLETED |
06/01/2012 | RESUB - SITE and/or GRADING | 06/20/2012 | COMPLETED |
06/20/2012 | RESUB - SITE and/or GRADING | 10/01/2013 | COMPLETED |
Outstanding Activity Conditions
Permit Number - DP12-0041
Permit Status: Complete
Permit Description: AREVA E IRVINGTON
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
06/07/2012 | The following 12 conditions apply to permit DP12-0041:1)Call for Pre-construction meeting. For a PDSD Engineering Inspection, call IVR (740-6970), or schedule with a Customer Service Representative at Planning & Development Services Department (PDSD), or contact PDSD Engineering at 837-4888, or schedule inspections online at: http://www.ci.tucson.az.us/dsd/Online_Services/Online_Permits/online_permits.html 2)This approved set of plans is approved for earthwork, grading construction, and drainage improvements associated with the AREVA solar project shown within the disturbance limits on the approved plans. 3)Designated staging area shall have no earthwork disturbance, and shall only be used for vehicular & material storage and temporary construction activities.4)A copy of stamped approved plan, permit(s), NOI, AzPDES general permit, and geotechnical report, shall be kept at site at all times, until final approval.5)Disturbance Limits shall be maintained and no disturbance outside of disturbance limits will be allowed. 6)Stabilized entrances shall be maintained at all active access entrances during construction. Use of water trucks during construction, or other dust controls shall be utilized, and construction entrances shall be maintained to minimize sedimentation, dust issues, and tracking.7)Interim erosion and sediment controls shall be maintained per approved plans at downstream areas of disturbance limits. Prior to Final Approval all temporary controls shall be removed and permanent controls shall be placed.8)After construction, all disturbed, graded, or bladed areas not otherwise improved or compacted shall be landscaped, reseeded, or provided with ground cover to help reduce dust pollution. If compacted areas after project completion show signs of dust issues or sedimentation, alternate ground treatment such as gravel or reseed will be required, and may be subject to fines if not addressed.9)Any revisions to the plan must be reviewed by PDSD Engineering Engineer and may include discussion, details, or a revised plan. Call PDSD Engineering at 791-5550 to discuss any revisions.10)If construction is expected to last longer than expiration date of permit, contact PDSD to renew/extend permit. If Final Inspection has not been completed before permit expires, and permit has not been renewed, additional fees and reviews may be required. Requests for permit extensions may be submitted to Planning & Development Services Department (attn: Claudia Buford), prior to permit expiration date, for consideration of plan extension approval.11)Permitee shall notify PDSD when operation is ready for final inspection. Final approval shall not be given until all work, including installation of all drainage improvements and their permanent protective devices, and all erosion control measures have been completed in accordance with approved plan and permit, and all conditions of permit are completed. 12)As-builts are required to be submitted under activity number DP12-0041 to PDSD permit clerks. They will be reviewed and then if acceptable, a copy will be provided to PDSD Engineering Inspector for final inspections. For Permit Project Closure documentation, submit: 2 copies of cover letter stating any changes to the approved plans, 2 copies of as-builts, and 2 copies of a letter for substantial completion of overall project. As-builts shall include: inverts for inlets and outlets for drainage pipes/systems, and general grades as determined by RLS to show substantial completion for project. |
Completed Inspections
Permit Status: Complete
Permit Number: DP12-0041
Permit Description: AREVA E IRVINGTON
Total Completed Inspections - 7
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/09/2013 | PDSD Engineering Division Pre-Construction SITE | Passed | {Activity date: 10/09/2013; Status: Approved; Inspector: MRUSSO; Comment: Entered by DROBERT5 - MET WITH SUPERINTENDENT, DISCUSSED SWPPP, REQUIREMENTS AND SITE/GRADING WORK. 1) USEEXISTING BIRMS FOR SEDIMENT CONTROLS AS MUCH AS POSSIBLE. IN AREAS WHERE BIRMS WILL BE REMOVED, INSTALL BMP'S UNTIL THE SITE IS STABILIZED. 2) INSTALL AND USE A STABILIZED CONSTR ENTRANCE 3) A COPY OF YOUR NOI HAS BEEN POSTED AT THE ENTRANCE TO THE SITE 4) INSTALL A CONCRETE/MATERIALS WASH OUT ON SITE WHEN APPLICABLE. 5) PERFORM AND DOCUMENT STORM WATER SELF INSPECTIONS PER YOUR PLAN. 6) SWEEP UP ANY TRACKED SOIL OF ADJACENT ROADWAYS AS NEEDED.} |
|
12/04/2013 | SITE - Stormwater Setup and Controls | Passed | {Activity date: 12/04/2013; Status: Approved; Inspector: MRUSSO; Comment: Entered by DROBERT5 - 1) ENSURE SEDIMENT CONTROLS ARE MAINTAINED THROUGHOUT CONSTRUCTION PER YOUR SWPPP. 2) PERIODIC FOLLOW UP INSPECTIONS WILL BE DONE TO DETERMINE IF ADDITIONAL CONTROLS ARE NEEDED AND THE SITE IS IN COMPLIANCE WITH AZPDES AND YOUR SWPPP.} ; {Activity date: 10/09/2013; Status: Partial Approval; Inspector: MRUSSO; Comment: Entered by DROBERT5 - MET WITH SUPERINTENDENT, DISCUSSED SWPPP, REQUIREMENTS AND SITE/GRADING WORK. 1) USE EXISTING BIRMS FOR SEDIMENT CONTROLS AS MUCH AS POSSIBLE. IN AREAS WHERE BIRMS WILL BE REMOVED, INSTALL BMP'S UNTIL THE SITE IS STABILIZED. 2) INSTALL AND USE A STABILIZED CONSTR ENTRANCE 3) A COPY OF YOUR NOI HAS BEEN POSTED AT THE ENTRANCE TO THE SITE 4) INSTALL A CONCRETE/MATERIALS WASH OUT ON SITE WHEN APPLICABLE. 5) PERFORM AND DOCUMENT STORM WATER SELF INSPECTIONS PER YOUR PLAN. 6) SWEEP UP ANY TRACKED SOIL OF ADJACENT ROADWAYS AS NEEDED.} |
|
12/13/2013 | ENGR Engineering Final | Passed | {Activity date: 12/13/2013; Status: Approved; Inspector: MRUSSO; Comment: Entered by DROBERT5 - GRADING HAS BEEN COMPLETED PER THE APPROVED GRADING PLAN} | |
12/13/2013 | SITE - Stormwater Follow-up | Passed | {Activity date: 12/13/2013; Status: Approved; Inspector: MRUSSO; Comment: Entered by DROBERT5 - SITE HAS BEEN COMPLETED PER THE APPROVED PLAN. SUBMIT A NOTICE OF TERMINATION TO ADEQ} ; {Activity date: 11/20/2013; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - NO SIGNIFICANT STORM WATER CONCERNS AT THIS TIME} ; {Activity date: 11/07/2013; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - CONTRACTOR SETTING GRADES AND SHAPING THE SITE. NO SIGNIFICANT STORM WATER CONCERNS AT THIS TIME} ; {Activity date: 10/31/2013; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - NO SIGNIFICANT STORM WATER CONCERNS AT THIS TIME} |
|
12/13/2013 | ENGR Grading Final | Passed | {Activity date: 12/13/2013; Status: Approved; Inspector: MRUSSO; Comment: Entered by DROBERT5 - } ; {Activity date: 12/04/2013; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - NO SIGNIFICANT SITE CHANGES AND/OR CONCERNS AT THIS TIME} ; {Activity date: 11/20/2013; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - NO SIGNIFICANT CHANGES AND/OR CONCERNS AT THIS TIME} ; {Activity date: 11/07/2013; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - CONTRACTOR SETTING GRADES AND SHAPING THE SITE. NO SIGNIFICANT STORM WATER CONCERNS AT THIS TIME} ; {Activity date: 10/31/2013; Status: Continued; Inspector: MRUSSO; Comment: Entered by DROBERT5 - CONTRACTOR ROUGH GRADING THE SITE PER APPROVED PLAN} |
|
12/13/2013 | SITE - Stormwater Final Inspection | Passed | {Activity date: 12/13/2013; Status: Approved; Inspector: MRUSSO; Comment: Entered by DROBERT5 - SITE HAS BEEN COMPLETED PER THE APPROVED PLAN. SUBMIT A NOTICE OF TERMINATION TO ADEQ} |
|
05/29/2019 | RSBU - Building Final | Passed | {Activity date: 05/29/2019; Status: Approved; Inspector: RLEDONNE; Comment: Entered by RLEDONN1 - } |