Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Parcel Search
 
Parcel Attributes
Parcel133190130
JurisdictionTucson, Pima County
Water Course

Wash

City of Tucson ZoningR-1
Tucson WardWard 2
Flood Related InformationFEMA Floodplain Area
Tucson Registered NeighborhoodEl Gheko
Pima County Data Assessor, Recorder, Treasurer, ...
Parcel Map Map
Address
Parcel Attributes Issue?

Annexations & Original City Zoning (OCZ)

Date - 11/21/2026 8:37 a.m.
Total Number Of OZC Plans - (1)
Plan Description Annexation Ordinance Effective Date OCZ Ordinance
C9-59-19 North To Roger Rd. And East To Kolb Rd. 1895 04/26/1959 1957

Permits

Parcel Number - 133190130
Date - 11/21/2026 8:37 a.m.
Total Number Of Permits - (5)
Permit Permit Status Entered Date Expired Date Unit Type Description
TR-ROW-0523-00779 Complete 05/17/2023 06/18/2023 Right-of-Way (ROW) EL GHEKO NA SPOT ONE 40YD OT ROFF AT 6736 E ROSEWOOD CIR ALONG CITY FENCED LOT WHICH IS NORTH OF 6746 E ROSEWOOD CIR
TC-RES-0725-03419 Complete 07/08/2025 01/12/2026 Residential Building - One or Two Family Gas Line Replacement Scope of work to replace gas line on property starting from meter to edge of home is as follows: -disconnect and remove all existing black iron piping from areas where it is accessible up to 6 feet above ground level on left side (from front) of house -Install new three-quarter inch 90 coming off of meter install three-quarter inch lead with 15 pound pressure gauge for future testing -run three-quarter inch piping down wall and through back wall mounting piping to wall per code with struts -install 1 inch PE adaptor under grade at no less than 12” to top of pipe. -run new section of 1 inch PE under trench to the left side of home to tie into 1 inch riser and install new mega ball valve- trench will be approx. 75 feet long burrowing under small brick path and drilling through one wall. Piping penetrating wall will need to be sleeved with ABS or PVC through the wall. -upon completion of install, we will perform a 15 pound gas pressure test for 30 minutes to ensure proper hold of pressure -upon pass test, we will leave line pressurized with air and finalize permitting process and schedule inspections. Overhead Gasline Replacement Upon secondary pressure test, if overhead is found to be leaking, we will replace all the gas lines from south edge of home up over ceiling, penetrating through roof to supply water, heater and furnace, and off the north side, dropping down the wall to supply the grill. All piping to be run in inch and a quarter gas piping. This line item is only necessary in the event that the overhead is independently leaking when tested.
T03CM05579 Final 12/02/2003 08/23/2004 COMBO ADDITION:PORCH:UPGRADE ELECTRIC:RELOCATE GAS LINE
T06EX00695 Closed 05/18/2006 07/17/2006 EXCAV 10 X10'D ADJ PRECAST MH/INST 212 COLLAR
T22RW02500 Final 07/13/2022 09/16/2022 ROW (2) 5x5 BELL HOLE IN DIRT TO ABANDON GAS LINE . CREWS MAY BE WORKING SATURDAYS FROM 7:00 AM TO 3:30 PM. ** PROOF OF NOTIFICATION IS REQUIRED AT THE TIME OF THE PRECONSTRUCTION MEETING. IN THE EVENT THAT WEEKEND OR AFTER-HOURS WORK IS INTENDED, CONTACT COT INSPECTION STAFF. DAN ROBERTSON AT 520-400-6722 OR TOM ADKINS AT 520-400-3813. Alley must be restored to existing or better condition. Alley surface must be graded and compacted to City Standards and Specifications for Public Improvements and existing drainage patterns must be restored and maintained. Any disturbed gravel must be replaced. NOTE: WORK IS BEHIND 6726 E ROSEWOOD CI ADDRESS ON APPLICATION - 6736 E ROSEWOOD CI