Parcel Search: 125091300
Parcel Search
Parcel Attributes
| Parcel | 125091300 |
|---|---|
| Jurisdiction | Tucson, Pima County |
| City of Tucson Zoning | R-1 |
| Tucson Ward | Ward 6 |
| Tucson Registered Neighborhood | Sam Hughes |
| National Register Historic District | Sam Hughes Residential Historic District |
| Structure on National Register of Historic Places | Contributor |
| Pima County Data | Assessor, Recorder, Treasurer, ... |
| Parcel Map | Map |
| Address | |
| Parcel Attributes Issue? | |
Annexations & Original City Zoning (OCZ)
Date - 11/23/2026 1:29 a.m.
Total Number Of OZC Plans - (1)
Permits
Parcel Number - 125091300
Date - 11/23/2026 1:29 a.m.
Total Number Of Permits - (11)
| Permit | Permit Status | Entered Date | Expired Date | Unit | Type | Description |
|---|---|---|---|---|---|---|
| C10-00-10 | Approved | 06/19/2009 | N/A | Zoning Verification Letter | C10-00-10 BARLIN / CARPORT ADDITION - - No | |
| TC-RES-0826-04491 | Issued | 08/12/2026 | 10/16/2027 | Residential Building - One or Two Family | Remove package unit and duct work off roof of addition, cap supply opening, and client will take care of indoor supply openings. Add 3 Cassette mini splits to home from 1 C/u that will be placed on the roof, using existing electrical. Will have access boxes on roof to get service access to cassettes. 2 1-ton machines will be put in addition main room, and the other in the sport/TV room. | |
| TC-RES-1026-05628 | Inspections | 10/09/2026 | 11/02/2027 | Residential Building - One or Two Family | replace portion of wall | |
| TC-RES-1122-00612 | Complete | 11/10/2022 | 12/23/2023 | Residential Building - One or Two Family | roof mount 13.86 kW DC photovoltaic solar system; 33 AC modules, 4 branches, 2 PV subpanels, 70A PV breaker on 225A bus with 200A MCB [new PV-ready service panel] | |
| T00BU00701 | Final | 03/06/2000 | 10/25/2000 | BUILD | ADDITION:CARPORT | |
| T00EX00499 | Closed | 03/30/2000 | 05/29/2000 | EXCAV | EXCAV:20 LF APRON:5 LF CURB CUT | |
| T13CM02628 | Final | 05/02/2013 | 12/08/2013 | COMBO | UPGRADE ELECTRIC 200 AMPS - RES | |
| T20BU00337 | Final | 08/24/2020 | 03/28/2021 | POOL/SPA | PC-POOL | |
| T21CM05792 | Final | 07/15/2021 | 04/11/2022 | COMBO | 85' of 2" gas line from main meter to pool equipment. | |
| T21CM09160 | Final | 11/24/2021 | 03/25/2023 | COMBO | Sleeping Quarters and Garage | |
| T99BU00954 | Withdrwn | 04/09/1999 | N/A | BUILD | ADDITION:CARPORT |
Code Enforcement
Parcel Number - 125091300
Date - 11/23/2026 1:29 a.m.
Total Number Of Code Cases - 1
| Case Number | Case Status | Entered Date | Closed Date | Unit | Type | Description |
|---|---|---|---|---|---|---|
| T22DV02614 | Complian | 04/25/2022 | N/A | DNR_VIOL | Permit violation, neighbor signed waiver agreeing to false information. |