Parcel Search: 122131590
Parcel Search
Parcel Attributes
| Parcel | 122131590 |
|---|---|
| Jurisdiction | Tucson, Pima County |
| City of Tucson Zoning | R-2 |
| Tucson Ward | Ward 6 |
| Tucson Registered Neighborhood | Garden District |
| Pima County Data | Assessor, Recorder, Treasurer, ... |
| Parcel Map | Map |
| Address | |
| Parcel Attributes Issue? | |
Annexations & Original City Zoning (OCZ)
Date - 08/17/2026 9:25 a.m.
Total Number Of OZC Plans - (1)
Permits
Parcel Number - 122131590
Date - 08/17/2026 9:25 a.m.
Total Number Of Permits - (9)
| Permit | Permit Status | Entered Date | Expired Date | Unit | Type | Description |
|---|---|---|---|---|---|---|
| T20CM06647 | Expired | 09/24/2020 | 03/29/2021 | E | Commercial Building | GAS RECONNECT |
| T09EL00853 | Final | 04/17/2009 | 01/31/2010 | #H | ELECT | replace electric receptical/wires |
| T09PL00938 | Final | 05/28/2009 | 03/13/2011 | #H | PLUMB | replace hot water heater |
| T11PL00728 | Expired | 04/18/2011 | 10/15/2011 | #E | PLUMB | REPLACE:WATER HEATER T11DV02025 |
| T12CM03914 | Final | 07/02/2012 | 12/30/2012 | #J | COMBO | ELECTRIC RECONNECT |
| T13CM07377 | Final | 12/06/2013 | 06/08/2014 | #F | COMBO | ADD NEW GAS LINE - APARTMENT |
| T15CM07924 | Final | 11/13/2015 | 05/21/2016 | #G | COMBO | REPL GAS LINE |
| T19CM08603 | Final | 11/20/2019 | 05/19/2020 | #H | COMBO | GAS RECONNECT |
| T98BU00682 | Expired | 03/18/1998 | 09/14/1998 | WALL/FEN | WALL:PATIO:250LF OF 6HI |
Code Enforcement
Parcel Number - 122131590
Date - 08/17/2026 9:25 a.m.
Total Number Of Code Cases - 5
| Case Number | Case Status | Entered Date | Closed Date | Unit | Type | Description |
|---|---|---|---|---|---|---|
| T09DV01720 | Courtcmp | 04/03/2009 | 06/08/2010 | DNR_VIOL | 4145 E FAIRMOUNT ST - HOMEOWNER DID ELECTRICAL WORK TO SAVE MONEY AND LADDER 7 IS ON SITE AND IT STATING THE WORK IS VERY DANGEROUS. | |
| T11DV00947 | Complian | 02/15/2011 | N/A | #C | DNR_VIOL | NO HEATING/COOLING OFF & ON FOR THE PAST SEVERAL MONTHS SINCE SUMMER. STATES CURRENTLY NOT WORKING PROPERLY. ALSO STATES AFFECTING ENTIRE COMPLEX. NOTE: INSPECTOR PLEASE CONTACT OCCUPANT PRIOR TO GOING OUT ONSITE. |
| T11DV02025 | Complian | 03/29/2011 | N/A | DNR_VIOL | APT #E WATER HEATER DOENS'T WORK - MANAGEMENT HAS DONE NOTHING FOR A FEW WEEKS NOW. WATER HAS BEEN LEAKING FOR AWHILE APT MANAGER # M | |
| T22DV02338 | Noverify | 04/08/2022 | N/A | DNR_VIOL | Couch at curb partially in street. Gray SUB parking g on Ped ROW. License plate Zaza AZ YYA10D. | |
| T99VL01611 | Closed | 06/18/1999 | N/A | CODEVIOL | COMPLAINT:BROKEN CLOSET DOORS, OTHER MIN HOUSING |