Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel Search

 
Parcel Attributes
Parcel117180860
JurisdictionTucson
City of Tucson ZoningHR-2
Water Course

Washes

Tucson WardWard 1
Tucson Registered NeighborhoodBarrio Viejo
National Register Historic District

Barrio El Hoyo Historic District

Structure on National Register of Historic Places

Contributing

Pima County Data Assessor, Recorder, Treasurer, ...
Parcel Map Map
Address

Annexations & Original City Zoning (OCZ)

Date - 11/22/2024 3:27 p.m.
Total Number Of OZC Plans - (1)
Plan Description Annexation Ordinance Effective Date OCZ Ordinance
Original Town Of Tucson ORIGINAL 08/07/1877 None

Rezoning Cases

Date - 11/22/2024 3:27 p.m.
Total Number Of Rezone Cases - (1)
Case No. Description New Zone Status Status Date Address
C9-74-20 Barrio Historic District HR-2 Effectuated 07/07/2011 S EL PASO

Permits

Parcel Number - 117180860
Date - 11/22/2024 3:27 p.m.
Total Number Of Permits - (3)
Permit Permit Status Entered Date Expired Date Unit Type Description
T00AN00837 Issued 10/16/2000 N/A #01 ADDRNEW
T00EL02437 Final 10/16/2000 06/04/2001 #01 ELECT UPGRADE:ELECTRIC FROM 30AMP TO 100AMP
T15EX00099 Final 02/09/2015 04/10/2015 EXCAV UNDERGROUND WORK This project is located in an Archaeological Sensitivity Zone. An Archaeological Monitor hired by the permit applicant is required to be on-site during any digging, unless a waiver is issued. Monitoring reports are to be submitted to Jonathan Mabry, Historic Preservation Office, City of Tucson, P.O. Box 27210, Tucson, AZ 85726.** Contact Jonathan Mabry at 520-837-6968 or jonathan.mabry@tucsonaz.gov with any questions. Tucson Water has approved the attached plan Zayo Fiber Solutions Downtown Music Hall 131 Granada Ave BPG Drawing E11568. Work Description: Zayo Group LLC proposes to trench and bore fiber optic conduits along Cushing St. and Granada Ave. The work will entail the crossing of several water mains. Tucson Water Review Findings: 1) It will be Zayo Group's and their contractor’s responsibility to avoid the water mains per City of Tucson/Pima County Standard Specifications for Public Improvements (5 foot horizontal and 1 foot vertical separation). Tucson water recommends potholing to ensure the standard is met. 2) The Tucson Water project data base number for future referencing of this project is 01554-6464. Summary & Recommendation: 1) Zayo Group is aware of Water facilities in the vicinity of the proposed work. 2) Zayo Group shall maintain Minimum Horizontal (5’) and Vertical (1’) separation requirements from Tucson Water facilities, as directed by the City of Tucson/Pima County Standard Specifications for Public Improvements. 3) Tucson Water will hold the contractor responsible for the cost of any water main repair and pavement replacement if the water utility is damaged during the directional bore construction. The contractor is to notify Tucson Water at 520-791-4133 in the event of a water main break. 4) Please approve the Right-of-Way permit application if this email from Tucson Water and the attached plan are included as instructions to the contractor. Please contact me if you have any questions. Walter Breitenstein, P.E. Tucson Water Distribution Design 310 W. Alameda P.O. Box 27210 Tucson, AZ 85726-7210 PROJECT-138C E11568 UNDERGROUND TOTAL FOOTAGE:2388'