Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Parcel Search
 
Parcel Attributes
Parcel117040160
JurisdictionTucson, Pima County
City of Tucson ZoningHR-2
Tucson WardWard 6
Tucson Registered NeighborhoodWest University
National Register Historic DistrictWest University Historic District
Structure on National Register of Historic Places

Contributor

Pima County Data Assessor, Recorder, Treasurer, ...
Parcel Map Map
Address
Parcel Attributes Issue?

Annexations & Original City Zoning (OCZ)

Date - 05/09/2026 10:07 p.m.
Total Number Of OZC Plans - (1)
Plan Description Annexation Ordinance Effective Date OCZ Ordinance
Original Town Of Tucson ORIGINAL 08/07/1877

Rezoning Cases

Date - 05/09/2026 10:07 p.m.
Total Number Of Rezone Cases - (8)
Case No. Description New Zone Status Status Date Address
C9-83-49 West University Historic District HB-1 Effectuated 09/23/2010 611 E 5TH
C9-83-49 West University Historic District HB-2A Effectuated 09/23/2010 611 E 5TH
C9-83-49 West University Historic District HB-2H Effectuated 09/23/2010 611 E 5TH
C9-83-49 West University Historic District HR-1 Effectuated 09/23/2010 611 E 5TH
C9-83-49 West University Historic District HR-2 Effectuated 09/23/2010 611 E 5TH
C9-83-49 West University Historic District HR-3 Effectuated 09/23/2010 611 E 5TH
C9-83-49 West University Historic District HR-4 Effectuated 09/23/2010 611 E 5TH
C9-83-49 West University Historic District HR-5 Effectuated 09/23/2010 611 E 5TH

Permits

Parcel Number - 117040160
Date - 05/09/2026 10:07 p.m.
Total Number Of Permits - (5)
Permit Permit Status Entered Date Expired Date Unit Type Description
TC-RES-0425-01870 Expired 04/09/2025 10/13/2025 Residential Building - One or Two Family Building permit applications and issued permits are subject to a 365-day expiration period. A permit application that is not actively pursued in good faith within 365 days of submittal is considered abandoned per IBC 105.3.2, as amended. If the project is to continue after abandonment, a new permit application must be submitted. Your application date was 04/09/2025. Main Electrical panel upgrade 200A. Underground service required for new pool install. Existing overhead service pole will need to be moved to E property line in same alleyway.
TR-UTL-0425-00598 Inspections 04/09/2025 05/16/2026 Right-of-Way (ROW) - Utility Electrical panel upgrade requiring a span of alleyway trench to service pedestal/pole 04/15/26- Renew Permit for 30 days as of 04/16/2026 new expiration date is 05/16/2026. 04/15/26- Denied Revision due to commentary revision was asking for an extension.
TC-RES-0426-02064 Inspections 04/22/2026 10/26/2026 Residential Building - One or Two Family Upgrade from overhead service to underground Service 200A
TC-RES-0426-02098 Needs resubmittal 04/23/2026 N/A Residential Building - One or Two Family Shotcrete Pool with Standard Model
TC-RES-0625-02923 Issued 06/06/2025 08/31/2026 Residential Building - One or Two Family Repair and Replace Roof System REV1_Sheet 1 Roof Framing Plan 1. Indicated existing plan with rafters @ 32' O.C. 2. Added new 2'x6' rafters between existing rafters for extra support for plywood and new shingle roofing. 3. Added section details to indicate type of rafters and to show rafter support.

Code Enforcement

Parcel Number - 117040160
Date - 05/09/2026 10:07 p.m.
Total Number Of Code Cases - 1
Case Number Case Status Entered Date Closed Date Unit Type Description
T10DV02265 Complian 04/16/2010 N/A DNR_VIOL Referral from ES, alley is overgrown with vegetation making it difficult for the drivers to service the alley containers.

Plans

Parcel Number - 117040160
Date - 05/09/2026 10:07 p.m.
Total Number Of Plans - 1
Plan Number Plan Status Application Date Expired Date Unit Type Description
SD-0925-00152 Complete 09/22/2025 N/A Special Districts Repair and Replace Roof System