Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Parcel Search
 
Parcel Attributes
Parcel116274530
JurisdictionTucson, Pima County
Water Course

Wash

City of Tucson ZoningR-1
Tucson WardWard 1
Pima County Data Assessor, Recorder, Treasurer, ...
Parcel Map Map
Address
Parcel Attributes Issue?

Annexations & Original City Zoning (OCZ)

Date - 09/22/2026 2:29 p.m.
Total Number Of OZC Plans - (1)
Plan Description Annexation Ordinance Effective Date OCZ Ordinance
C9-82-62 Quien Sabe 5687 01/05/1983 5804

Rezoning Cases

Date - 09/22/2026 2:29 p.m.
Total Number Of Rezone Cases - (1)
Case No. Description New Zone Status Status Date Address
C9-83-01 Starr Pass Estates - Starr Pass Boulevard R-1 Closed 07/19/2012 3430 W RED BIRD

Special Development Requests & Requirements

Date - 09/22/2026 2:29 p.m.
Total Number Of Special Development Permits - (1)
Activity Number Status Apply Date Expired Date Type Description
H000010760 Closed N/A

Permits

Parcel Number - 116274530
Date - 09/22/2026 2:29 p.m.
Total Number Of Permits - (2)
Permit Permit Status Entered Date Expired Date Unit Type Description
T21CM06111 Withdrwn 07/27/2021 N/A COMBO I am converting a 120V 20A branch circuit (currently feeding the furnace in the air handler closet) to a 240V 15A branch circuit (to feed a new air handler in the same closet) per the attached wiring diagram. Complicating the project is the fact that the electrical panel was wired (in 1995) with multi-wire branch circuits. So breakers #17 (furnace - red wire) and #19 (washer - black wire) use the same 12/3 romex cable and share its neutral white wire. In order to convert #17 (and #19) slots to 240V, I will need to move the #19 breaker to the #27 slot and run a separate 12/2 romex cable from #27 to the "washer" wiring located in a junction box (in the sealed crawl space above the laundry room). This will free up the black and white wires currently used by #19. The #17 1-pole 20A circuit breaker will then be replaced with a 2-pole 15A HACR circuit breaker (per the new air handler spec) in slots #17 and #19. Breaker #17's white wire will be moved from the neutral bus to the #19 breaker, and re-id'd with black marker. The now-unused black wire will be capped with a wire nut. Finally, the 120V 15A fused outlet currently in the air handler closet will be replaced with a 240V 30A non-fuse disconnect switch.
T97BU01179 Final 06/25/1997 07/13/1998 POOL/SPA POOL & SPA:DUPL # 13-55-95