Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Parcel Search
 
Parcel Attributes
Parcel116130610
JurisdictionTucson, Pima County
City of Tucson ZoningR-1
Tucson WardWard 1
Tucson Registered NeighborhoodSantiago Hills
Pima County Data Assessor, Recorder, Treasurer, ...
Parcel Map Map
Address
Parcel Attributes Issue?

Annexations & Original City Zoning (OCZ)

Date - 08/17/2026 6:10 p.m.
Total Number Of OZC Plans - (1)
Plan Description Annexation Ordinance Effective Date OCZ Ordinance
C9-60-39 West To Silverbell Road And South To San Xavier Indian Reservation 2014 03/18/1960 2045

Permits

Parcel Number - 116130610
Date - 08/17/2026 6:10 p.m.
Total Number Of Permits - (7)
Permit Permit Status Entered Date Expired Date Unit Type Description
C10-03-01 Efectuat 12/16/2008 N/A LUCAPHST C10-03-01 MALDONADO RESIDENCE CARPORT ADDITION (T02BU00377) The applicant's property is a 9,200 square foot lot developed with an existing 1,411 square foot single-family residence with two existing carports, one of which will be enclosed to create a room addition. The applicant proposes completion of a new partially constructed entry and carport addition to the front of the residence. The applicant is requesting a variance to reduce the front street setback of the carport to 13'5". DECISION: VARIANCE 1: GRANTED WITH CONDITIONS. A. Carport not to be enclosed. B. No cars parked between carport and street.
T02BU00377 Final 02/06/2002 12/03/2003 BUILD ADDITION:EXTEND CARPORT & PORCH AT FRONT T02VL00112
T05BU00189 Final 01/27/2005 03/01/2006 BUILD ADDTION:COVERED PORCH
T05CM06486 Final 12/29/2005 08/04/2009 COMBO ENCLOSE:CARPORT:BACK PORCH REV1:CHANGE WINDOW AND DOOR SIZES,ADD CLOSET ANDSMOKE DETECTORS
T19CM05278 Final 07/25/2019 03/03/2020 COMBO E- INSTALL PV SYSTEM AND RELATED MATERIALS
T20RW00780 Final 02/07/2020 03/12/2020 ROW 2 5x5 bellholes in dirt alley---- to relocate gas meter COYL PROJECT NOTES: Alley must be restored to existing or better condition. Alley surface must be graded and compacted to City Standards and Specifications for Public Improvements and existing drainage patterns must be restored and maintained. Any disturbed gravel must be replaced.
T98EL01090 Final 06/15/1998 12/15/1998 ELECT UPGRADE:ELECTRIC:60AMP TO 200AMP

Code Enforcement

Parcel Number - 116130610
Date - 08/17/2026 6:10 p.m.
Total Number Of Code Cases - 1
Case Number Case Status Entered Date Closed Date Unit Type Description
T02VL00119 Complian 01/18/2002 N/A CODEVIOL COMPLAINT:CARPORT/PORCH WOP.