Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Parcel Search: 113010020
Parcel Search
Parcel Attributes
| Parcel | 113010020 |
|---|---|
| Jurisdiction | Tucson, Pima County |
| City of Tucson Zoning | MH-1 |
| Tucson Ward | Ward 3 |
| Tucson Registered Neighborhood | Campus Farm |
| Major Street & Route | Gateway Route, Arterial or Collector |
| Pima County Data | Assessor, Recorder, Treasurer, ... |
| Parcel Map | Map |
| Address | |
| Parcel Attributes Issue? | |
Annexations & Original City Zoning (OCZ)
Date - 12/19/2025 1:48 p.m.
Total Number Of OZC Plans - (1)
Rezoning Cases
Date - 12/19/2025 1:48 p.m.
Total Number Of Rezone Cases - (2)
Permits
Parcel Number - 113010020
Date - 12/19/2025 1:48 p.m.
Total Number Of Permits - (6)
| Permit | Permit Status | Entered Date | Expired Date | Unit | Type | Description |
|---|---|---|---|---|---|---|
| T10SE00100 | Approved | 06/30/2010 | N/A | Zoning Compliance | A special exception request to install two new 2-foot microwave dishes on an existing 61'4" foot ta | |
| TR-ROW-1025-01260 | Complete | 10/08/2025 | 12/24/2025 | Right-of-Way (ROW) | Daytime closure for cell tower work 11-24 thru 11-26-25*** 1805 E ROGER RD | |
| TC-COM-1122-00196 | Void | 11/30/2022 | N/A | Commercial Building | VOID - WRONG PERMIT TYPE · INSTALL (2) NEW AT&T ANTENNA WITH INTEGRATED RRH UNIT PER SECTOR, (3) SECTORS, (6) TOTAL ON POSITION 1 · INSTALL (1) NEW DC9 SURGE · INSTALL (1) NEW 24 PAIR FIBER CABLE · INSTALL (3) NEW 6AWG DC CABLES · INSTALL (1) WCS FILTER FOR BETA SECTOR ON POSITION 3 · REMOVE (6) EXISTING TMAs PER SECTOR, (3) SECTORS, (18) TOTAL · REMOVE (3) EXISTING ANTENNAS PER SECTOR, (3) SECTORS, (9) TOTAL · INSTALL (2) NEW ROSENBERGER #2 GROUND WIRE PER MFG. SPEC'S FOR ALL NEW INSTALLATIONS · REMOVE (6) LINES OF COAX CABLES CHANGES IN THE EXISTING AT&T EQUIPMENT ENCLOSURE AREA: (NO NEW SHELTER PROPOSED) · INSTALL (6) NEW RRHs · INSTALL (1) NEW FLEX21 CABINET · INSTALL (6) NEW TRIPLEXERS · REMOVE (12) EXISTING RRHs · REMOVE (1) EXISTING LTE CABINET · REMOVE (6) EXISTING QUADPLEXERS AC/DC SCOPE: DC POWER PLAN REVIEW: · EXISTING VERTIV NETSURE 512 -48VDC POWER PLANT [NEQ.19918] OUTFITTED WITH (10) HE 2KW -48VDC RECTIFIERS [NEQ. 15930] & (3) HE 1.5KW -48VDC/+24VDC CONVERTER MODULES [NEQ. 15929]. INSTALL (1) ADDITIONAL HE 2KW -48VDC RECTIFIER [NEQ. 15930] TO MEET N+1 REQUIREMENT. · NEW DC BREAKERS IN EXISITNG POWER PLANT AS FOLLOWS ·· (2) 100A [NEQ. 00187] FLX21-2520 ·· (3) 50A [NEQ.00710] AIRSCALE DUAL BAND B25/66 AHFIB ·· (3) 50A [NEQ.00710] AIRSCALE DUAL BAND B12/14 AHLBA ·· (6) 40A [NEQ.00185] AEQ SERIES BATTERY CHECK: · BATTERY RESERVE CAPACITY: REMOVE (32) EXISTING MARATHON M12V155FT BATTERIES. INSTALL (12) NEW GNB M12V180FTX BATTERIES [NEQ.19872] IN BOTTOM SECTION OF NEW DC POWER SYSTEM. INSTALL (20) NEW GNB M12V180FTX BATTERIES [NEQ.16622] IN VERTIV NETXEND FLEX BATTERY CABINET. CONFIGURE BATTERIES FOR -48V OPERATION AS (4) CELLS PER STRING. FIVE BATTERY STRINGS WILL PROVIDE 4.2 HOURS OF BATTERY BACKUP. · NO PERMANENT STANDBY GENERATOR, MINIMUM REQUIRED BATTERY BACKUP TIME IS 4.0 HOURS. A/C PANEL REVIEW: · SEE PANEL SCHEDULE HVAC UNITS: · SITE HAS TWO EXISTING 4-TON HVAC UNITS, WHICH ARE SUFFICIENT | |
| T08CM01143 | Expired | 04/10/2008 | 02/25/2009 | COMBO | NEW: ELECTRICAL GROUND CABINET AND 6' WALL; COMMERCIAL. NEW UTILITY POLE (64') TO REPLACE EXISTING POLE | |
| T15CM02092 | Final | 03/31/2015 | 07/26/2016 | COMBO | CELL TOWER | |
| T19RW07527 | Final | 12/13/2019 | 02/14/2020 | ROW | SPEED FEEDBACK PROGRAM - PLEASE SEE DRAWING Park speed feedback trailer away from edge of road. See schematic - To Place speed feedback trailer along Curb line to catch travel direction. Trailers located approximately 600 feet East and West of Permit Location on map @ 1612 E ROGER RD. |
Code Enforcement
Parcel Number - 113010020
Date - 12/19/2025 1:48 p.m.
Total Number Of Code Cases - 1
| Case Number | Case Status | Entered Date | Closed Date | Unit | Type | Description |
|---|---|---|---|---|---|---|
| T07DV04031 | Invalid | 05/02/2007 | N/A | DNR_VIOL | OPERATION OF A BUSINESS WITH NO C of O OR SITE PLAN APPROVAL. - (ROBERT DEAR INSPECTOR) |
Plans
Parcel Number - 113010020
Date - 12/19/2025 1:48 p.m.
Total Number Of Plans - 1
| Plan Number | Plan Status | Application Date | Expired Date | Unit | Type | Description |
|---|---|---|---|---|---|---|
| T17PRE0009 | Closed | 01/23/2017 | N/A | NEIGHBORHOOD NOTIFICATION |