Inspection History Details
Inspection Status: Passed
Inspection History: Consultation SITE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/06/2025 | Consultation SITE | Passed | Notes on site; 1) lower all tube scuppers 2" 2) left side walk needs to be 1 continuous slope vs. 2 different slopes and top of ram need to have a 5' turnaround. 3) sidewalk going to front rd sidewalk needs to have a flat spot at the sidewalk parking area section and them slope to rd sidewalk. |
|
| 08/14/2025 | Consultation SITE | Passed | Site walk to access progress: 1. Install remaining scuppers. 2. Correct safety issue on North wall; top course is loose. 3. Ensure compaction of sub-grade (95%) and AB (100%) as well as positive drainage from parking lot. 4. Clear vegetation from sidewalk space (width of sidewalk and 84" high) 5. Curb cut to open driveway to 24' |