Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit: TD-DEV-1224-00334

Parcel: 14020002F


Addresses:

4940 S PARK AV

Inspection Status: Partial Pass

Inspection History: ENGR - Drainage Structures

Date Description Inspector Results Comments
04/28/2026 ENGR - Drainage Structures Partial Pass 24" HDPE. Last section of Pipe from STA 5 + 15.98. Upgrade to end of pipe at STA 9+83.79. Pipe is set with survey offsets and elevations nails in place. Slope along length is reasonably +/- .5% Joints look tight and correct. Sealant visible inside Basin joints to pipe. Trenching/Bedding is good okay to backfill. Submit density results to the portal.

Note: Port a John’s will be staked for next inspection.