Permit: TD-DEV-0924-00259

Parcel: 14103038B


Addresses:

7040 E VALENCIA RD

Inspection Status: Not Ready

Inspection History: ENGR - Drainage Structures

Date Description Inspector Results Comments
04/09/2026 ENGR - Drainage Structures Not Ready This is a drain pipe inspection. 6 inch HDPE drain pipe connecting basins one and two is not trenched correctly. Trench is barely over 6 inches wide. The result is a bowed drainpipe that cannot be bedded correctly.
The other 6” HDPE drain pipe from basin 1 and out into stormwater channel is correct. This drain pipe is OK to backfill. Trim end of pipe and seal it cleanly at gunite channel. Reschedule inspection when drain pipe is trenched correct correctly with clearance on each side.