Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Scheduled
Inspection History
Permit Number - TD-DEV-0924-00254
Inspection Description -
Inspection Status - Scheduled
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| Scheduled | ||||
| 02/03/2026 | Partial Pass | 2/3/26 10 supercharger foundations cast in place per detail C-2 on page C201 1 double cast in place foundation per detail B-1 on page C203 Forms are correct, 6" ABC compacted with Jumping Jack and filter fabric in place correct. 4 #5 hors w/ 5 #4 ties. They are adjacent to existing curb, and in line with new curb that will be poured. -double foundation placed between 2 10.5' parking spaces. Forms layed out to plan and detail. Okay to pour forms Small section of sidewalk in island ready for pour. 6” wire remesh per detail placed. Okay to pour sidewalk Schedule inspection for paving, striping, and light pole footers |