Inspection Status: Failed
Inspection History: ENGR Paving
| Date |
Description |
Inspector |
Results |
Comments |
| 05/20/2026 |
ENGR Paving |
|
Failed |
No compaction reports were given. TSM Section 7-04.2 requires physical separation between vehicle area and sidewalk. There is only 4" of vertical separation. The minimum vertical separation is 6". At west side of lot the vertical separation tapers to 0". I need written a written acceptance letter of this verical separation and of all plan changes by site Engineering. (You mentioned Steven Blood). |
| 05/28/2026 |
ENGR Paving |
|
Passed |
|