Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Partial Pass
Inspection History
Permit Number - TD-DEV-0623-00280
Inspection Description -
Inspection Status - Partial Pass
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/21/2025 | Partial Pass | Call in grading inspection as grading progresses. We will be looking at the basin elevations and inlets and outlets/weir to verify elevations. We need to look at the Drywell as that is being installed to ensure that is correct. The 12” storm drain pipe in the loading dock and to the manhole and Basin #1 will need to checked for elevation, slope bedding etc. Also the 18” Basin outflow. Be certain to call in Drainage Pipe and structures inspections as you get there for us to look at it. | ||
| 08/04/2025 | Partial Pass | Initial rough grading has started. Basin has been cut. Loading dock area has been cut. Now would be a good time to add a compacted berm to the west side of basin. As Grading progresses call us back in to check slopes when ready. Compaction test results will be needed for Subgrade in graded areas. These will be need to be submitted to the portal when ready. |