Inspection History: SITE - Stormwater Setup and Controls
Permit Number - TD-DEV-0523-00249
Inspection Description - SITE - Stormwater Setup and Controls
Inspection Status - Passed
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/24/2025 | SITE - Stormwater Setup and Controls | Passed | 9/24/25 Wattle at perimeter is beginning to break down and will need to be replaced in areas where it is torn up. Lap joints minimum of 2'. Stake it correctly and where it goes over hardscape use sandbags per detail. Inlets protection needs to be checked. Filter fabric should be used per details and needs to be secured all around under grates. Currently plastic sheet is used but much of it is frayed with holes at edges. Some are being covered with dirt. If Superintendent prefers plastic sheet on some inlets that are not connected that is ok, check with him. Trackout needs to be reconditioned and have rock added per plan. Trackout Inlet protection fabric Wattle |
|
| 11/13/2023 | SITE - Stormwater Setup and Controls | Not Ready |